6
x
Parameter settings
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
51
6.10 Rotary switch setting: Info
Parameter
Description
Access
Setting range
Min / Max
Factory
setting
Increment
BE
HF
Overview
Display of different current operating data (see section 3.4.1).
S
S
-
-
-
Water Pressure
The current water pressure is displayed in bar.
S
S
0 - 4 bar
-
0.1 bar
T-HS
The current temperature (TVBH) of the heat generator is displayed in °C.
S
S
0 - 100 °C
-
1 °C
T-HS Setpoint
The current Inflow target temperature of the heat generator is displayed in °C
(see section 3.6.4).
S
S
0 - 90 °C
-
0.1 °C
T-Outside
The average external temperature is displayed °C.
S
S
-39 to +50 °C
0.1 °C
T-DHW
The current temperature of the hot water storage tank is displayed in °C. If there is no hot
water function activated, "- - -" is displayed.
S
S
0 - 100 °C
-
0.1 °C
T-DHW Setpoint
The current target hot water temperature is displayed °C. If there is no hot water function ac-
tivated, "- - -" is displayed. The current set value is here always the maximum value of all
relevant demands for this hot water circuit.
S
S
10 - 70°C
-
0.1 °C
T-Return
The current return flow temperature of the heat generator is displayed in °C. If there is no
relevant sensor connected to the heat generator, "- - -" is displayed.
S
S
0 - 100 °C
-
0.1 °C
Flow Rate
The filtered value of the current volume flow in litres per hour is displayed.
S
S
0 - 5100 l/h
-
l/h
T-HC
The inflow temperature in the direct heating circuit is displayed in °C.
S
S
0 - 100 °C
-
0.1 °C
T-HC Setpoint
The set temperature of the flow in the direct heating circuit is displayed in °C.
S
S
0 - 90 °C
-
0.1 °C
Status HS pump
The current status of the internal heat circulation pump in the Daikin Altherma EHS(X/H) is
displayed.
S
S
Off
On
-
-
Runtime Compres-
sor
The running time of the refrigerant compressor is displayed in h.
S
S
-
-
h
Runtime Pump
The running time of the internal heating circulation pump is displayed in h.
S
S
-
-
h
Mixer Position
The current position of the 3UV DHW 3-way switch valve is displayed.
0%: Position A (room heating)
100%: Position B (domestic hot water generation)
S
S
0 - 100 %
-
1 %
Qboh
The amount of heat in the additional heat generator for hot water generation is displayed in
kWh.
S
S
-
-
kWh
Qchhp
The amount of heat in the additional heat generator for heating mode is displayed in kWh.
S
S
-
-
kWh
Qsc
The quantity of heat in the heat pump for cooling is displayed in kWh.
S
S
-
-
kWh
Qch
The quantity of heat in the heat pump for heating is displayed in kWh.
S
S
-
-
kWh
QWP
The total amount of heat in the heat pump is displayed in kWh.
S
S
-
-
kWh
Qdhw
The quantity of heat for hot water generation is displayed in kWh.
S
S
-
-
kWh
HS type
The heat generator type Daikin Altherma EHS(X/H) detected is displayed.
S
S
-
-
-
Sw Nr B1/U1
The software and version of the control unit RoCon B1 B1 /
of the room station
EHS157034is displayed.
S
S
-
-
-
Sw Nr Controller
The software number and the version of the RoCon BM1 circuit board are displayed.
S
S
-
-
-
Sw Nr RTX RT
The software number and the version of the RTX-AL4 circuit board are displayed.
S
S
-
-
-
Tab. 6-12 Parameter in rotary switch setting "Info"
6.11 Exit button: Sonderfunktion
Depress the exit button for at least 5 secs. for access.
Parameter
Description
Access
Setting range
Min / Max
Factory
setting
Increment
BE
HF
Manual Operation
The direct heating circuit and the target hot water temperature are controlled according to
the temperature set in this parameter (see section 3.5.1).
E
E
20 - 80 °C
50 °C
1 °C
FA failure
Display of a current heat pump malfunction in the Daikin Altherma EHS(X/H).
If "----" is displayed there is no fault (see chapter 7).
E
E
-
-
-
Protocol
Display of protocol (error and information messages). Here we display the saved messages
of the Daikin Altherma EHS(X/H) and the connected RoCon system components with date
and code as a menu entry in each case. By selecting an entry to using the rotary switch, all
other corresponding information is displayed concerning the selected message:
- Date and time of the message
- Code number (Information for the heating technician)
- Device type from which the message comes
- Device ID for the RoCon unit where the message originates
E
E
-
-
-
Delete message
By setting this parameter to "On" and briefly pressing the rotary switch, all entries in the re-
port, including the faults from connected RoCon system components, are deleted.
E
E
Off
On
Off
-
RoCon B1/U1 Reset Resets all parameter settings to factory setting. Required for software updates or changes
to the RoCon system (see chapter 4.2). Complete reconfiguration subsequently required.
N
E
Off
On
Off
-