Operating instructions
10
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
3
x
Operation
Rotary switch
The rotary switch can be used to navigate in the individual levels,
setting values can be selected, changed and these changes can
then be accepted by pressing briefly.
Action
Result
Rotating
To the right (+): Increased regulation
To the left (–): Reduced regulation
Pressing
Confirm, accept, selection and execute the
function.
Tab. 3-3 Functions of the rotary switch
Exit button
This button can be used to jump back to the previous display
within a menu display or a function / input can be interrupted.
This button can also be used to call up the special level
(see section 3.5).
Action
Result
Brief pressing.
– Jump back to the previous display or pre-
vious level or
– Cancellation of a special function or an
active temporary timer programme.
Pressfor more
than 5 secs.
– Special level is called up.
Tab. 3-4 Functions of the exit button
3.3
Operating concept
The operating concept for controlling the RoCon HP is structured
in such a way that the frequently required settings options are ac-
cessible quickly and directly at the
main function level
(selection
using the
rotary switch
), while the less frequently required set-
tings options are arranged at a lower parameter level.
1
Info (section 3.4.1)
2
Operating Mode (section 3.4.2)
3
Set Temp Day (section 3.4.3)
4
Set Temp Night (section 3.4.4)
5
DHW Set Temp (section 3.4.5)
6
DHW Install (section 3.4.6)
7
Time Program (section 3.4.7)
8 Configuration
(section 3.4.8)
9
Remote Param (section 3.4.9)
Fig. 3-3
Illustration of main function level (rotary switch position)
Certain functions and parameters are restricted by access au-
thorisation and can only be adjusted by the heating technician
(see section 3.6.1).
In normal operating mode the rotary switch should be in
position
.
After switching on and successful initialisation, the display auto-
matically shows the standard display with rotary switch
position
.
In the first commissioning, the setting for language selection is
displayed first.
●
Select the language using the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
Adaption to the special installation configuration is
carried out in the
"Configuration"
rotary switch
position (see section 3.4.8).
When the system is switched on, based on the stipulations set in
the Controller RoCon HP, it fully automatically regulates the
operation of the
– room heating, room cooling and the
– sanitary hot water generation.
Independent of the setting of the rotary switch, the
Daikin Altherma EHS(X/H) operates in accordance with
the operating mode set in the
"Operating Mode"
switch position or that has been activated by a
special programme.
If the user enters a value manually, this setting remains active
until the user changes it or until the programme clock forces an-
other operating mode.