![Daikin EHS157034 Operating Instructions Manual Download Page 15](http://html.mh-extra.com/html/daikin/ehs157034/ehs157034_operating-instructions-manual_501784015.webp)
Temporary
timer
programme
Setting /
activating in
level
Rotary
switch
setting
Note
DHW Install
DHW Install
section
Party
Time Program
section
Away
Holiday
Vacation
Screed*
Configuration >
HC Configura-
tion
section
3
x
Operation
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
15
* only with expert code.
Tab. 3-7 Overview of temporary timer programmes
If a temporary timer programme (DHW Install, Party,
Away, Holiday, Vacation, Screed) is started during the
selected operating mode, the regulation will take place
with preference according to the settings of this timer
programme.
3.4.3 Temperature setting Daytime room temperature
The set room temperatures for room heating during the day are
determined in the rotary switch setting
.
●
Place the rotary switch in the
"Set Temp Day"
position.
An overview is displayed.
The end figures of the parameter designations (1 - 3)
within this rotary switch setting designate the associ-
ation with each individual cycle of the timer programme.
●
Select the temperature block to be set with the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
Settings are displayed.
●
Set the temperature.
●
Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.5.
3.4.4
T
emperature setting Economy mode
The set room temperatures for room heating in economy mode
are determined in the rotary switch setting
.
●
Place the rotary switch in the
"Set Temp Night"
position.
An overview is displayed.
●
Select the parameter to be set with the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
– [T-Reduced]: Set value for "Reducing" operating mode or
setback by a permanent timer programme.
– [T-Absence]: Set value for temporary heating / cooling
programmes ("Away" and "Vacation").
Settings are displayed.
●
Set the temperature.
●
Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.6.
3.4.5 Temperature setting hot water generation
The hot water set temperatures for hot water generation for each
individual timer programme are determined in the rotary switch
setting
.
●
Place the rotary switch in the
"DHW Set Temp"
position.
The end figures of the parameter designations (1 - 3)
within this rotary switch setting designate the associ-
ation with each individual cycle of the timer programme.
●
Select the temperature block to be set with the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
Settings are displayed.
●
Set the temperature.
●
Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.7.
3.4.6 Unscheduled hot water generation
You can charge the hot water up manually outside a hot water
timer programme to the preset temperature set in parameter
[T-DHW Setpoint 1] in the rotary switch position
. Heating up
is carried out as a priority and independently of any other heating
programmes.
●
Place the rotary switch in the
"DHW Install"
position.
An overview is displayed.
●
Select the parameter to be set with the rotary switch.
– [1x Hot Water]: Activating one-off hot water generation.
●
Confirm the changes with a brief push of the rotary switch.
●
Setting parameters
●
Confirm the changes with a brief push of the rotary switch.
Begin unscheduled hot water generation.
After this temporary function has expired, the Controller
automatically jumps back to the previously active oper-
ating mode. The rotary switch should therefore be re-
turned to the position
"Info"
after activation.
The function is subject to time limits.
It is interrupted at the latest after the maximum charging
time set in the parameter [Max DHW loading ] and
cannot be restarted once more until the blocking time
set in the parameter [DHW Off Time] has expired
(see chapter 6.2.4).
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.3.