![Daikin EHS157034 Operating Instructions Manual Download Page 23](http://html.mh-extra.com/html/daikin/ehs157034/ehs157034_operating-instructions-manual_501784023.webp)
Configuration
Setup
System
Configuration
System
HC Configuration
DHW Configuration
HC Configuration
HC Function
T-Frost Protect
Heating
T-Outside lim night
Heat-Slope
Room Influence
Heat-Slope
Heat-Slope
Heat-Slope
HC Configuration
Insulation
Heating
Cooling
Fig. 3-14 Manual setting of the heat curve (shown for "User" access
rights)
T
A
External temperature
T
R
Room temperature set value
T
V
Flow temperature
Fig. 3-15 Heat curves
3
x
Operation
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
23
More detailed explanations and possible setting values for this function can be seen
in chapter 6.2.
3.6.3 Cooling characteristic curve
Caution! - risk of condensation!
In the event of a fault or wrong setting of
parameters, damage may be caused to
the screed, the structure of the floor and
the underfloor heating system by con-
densation.
●
Before initial commissioning and
activation of cooling operation, set the
maximum permissible system
temperature in the minimum temper-
ature limit in the Controller RoCon HP
(parameter [Min T-Flow Cooling]).
With the cooling characteristic curve, the inflow target temper-
ature is adjusted to suit building conditions in accordance with the
relevant external temperature (weather-controlled flow temper-
ature regulation, see section 3.6.4). Warmer outdoor tempera-
tures result in a colder inflow target temperature and vice versa.
Conditions for
cooling operation
:
– Outside temperature > target room temperature setting
– Outside temperature > [Start T-Out Cooling] parameter set-
ting
– Operating mode
"Cooling"
activated.
a) with the rotary switch in the
"Operating Mode"
position or
b) via the room thermostat function (cooling
switching
contact closed)
– No heating demand in the RoCon system of the heating
installation.