Page 1: ...Operating instructions Daikin RoCon HP EHS157034 EHS157068 Daikin Controller RoCon HP EHS157034 EHS157068 Operating instructions Daikin Controller RoCon HP EHS157034 EHS157068 English ...

Page 2: ... 4 2 Room station EHS157034 35 4 4 3 Allocating mixing module EHS157068 to a heat generator 36 4 4 4 Master RoCon function 36 4 4 5 Caretaker function 36 5 Parameter Overview 37 5 1 For first commissioning or resetting to factory settings 37 5 2 After first commissioning after successful basic configuration 38 5 2 1 Rotary switch setting Configuration 38 5 2 2 Rotary switch setting DHW Install 39 ...

Page 3: ...kin Controller 008 1420844_13 02 2016 Operating instructions 3 9 Notes 59 9 1 User specific settings 59 9 1 1 Switching timer program 59 9 1 2 Parameter 60 9 1 3 IDs in the RoCon CAN bus system 60 9 2 Other items 61 10 List of keywords 63 ...

Page 4: ...so ciated installation and operating instructions If a Daikin FWXV 15 20 AVEB is connected the associated installation and operating instructions If a different heater or optional accessories are connected the associated installation and operating instructions The guides are included in the scope of supply for the individual units 1 2 Warning signs and explanation of symbols 1 2 1 Meaning of the w...

Page 5: ...te the Daikin Altherma EHS X H as stipulated and in perfect condition with an awareness of safety and the hazards involved This assumes knowledge and use of the con tents of this manual of the relevant accident pre vention regulations as well as the recognised safety related and occupational health rules WARNING 1 4 Proper use The RoCon HP may be used only in Daikin Altherma EHS X H heat pumps tha...

Page 6: ...s demand from an external heat generator switching to bivalent operating mode external status display etc In addition it also has several inputs for assessing external control contacts external operating mode switching or heat demand SMART GRID and low tariff EVU functions 1 1 Energy supply company EVU sends signals that are used for controlling the power mains loading and which have an influence ...

Page 7: ...ation The most effective energy utilisation is achieved by the Daikin Altherma EHS X H at the lowest possible return flow and hot water temperatures If an external heat generator e g the optional Backup Heater is used at inflow target temperatures of over 50 C the efficiency COP of the Daikin Altherma EHS X H can be affected negatively depending on the outside temperature 3 2 Display and operating...

Page 8: ...ndicates the operational status and the operational mode White Standard lighting normal operational display Red Fault status depending on the type of fault the Daikin Altherma EHS X H continues to function with restrictions Green Operating mode with operator authorisation Blue Operating mode with expert technician authori sation 1 Date display 2 Status of refrigerant com pressor 3 Status display e...

Page 9: ...cuit status Heating circuit active room heating function Heating circuit active room cooling function Heating circuit not active currently no heat transfer in the heating circuit 7 Outside temperature sensor The current outside temperature is dis played 8 Current operating mode see section 3 4 2 Standby active Reducing active Heating active Cooling active Summer active Automatic 1 active Automatic...

Page 10: ...on 3 4 2 3 Set Temp Day section 3 4 3 4 Set Temp Night section 3 4 4 5 DHW Set Temp section 3 4 5 6 DHW Install section 3 4 6 7 Time Program section 3 4 7 8 Configuration section 3 4 8 9 Remote Param section 3 4 9 Fig 3 3 Illustration of main function level rotary switch position Certain functions and parameters are restricted by access au thorisation and can only be adjusted by the heating techni...

Page 11: ...ank temperature 35 C the backup heater BUH is switched on automatically on in order to heat up the storage tank water to at least 35 C In order to accelerate the heating process with the back up heater temporarily Parameter Function Heating 1 and Set parameter Power DHW to the maximum value of the back up heater Set rotary switch to the operating mode and parameter 1x Hot Water to On Automatic def...

Page 12: ...rameter Room thermostat On Heating or cooling demand No heating demand Parameter Interlink fct On priority only frost protection IL1 normal inflow target temperature IL2 increased inflow target temperature in heating operation decreased inflow target temperature in cooling operation Pump Actual output of the internal heating circulation pump in EHS Current output of the backup heater in kW BPV Cur...

Page 13: ...H is to operate is undertaken on the rotary switch in the setting Operating Mode The selected operating mode is activated by briefly pushing the rotary switch Operating Mode Standby Reducing Operating Mode Heating Cooling Summer Operating Mode Summer Automatic 1 Automatic 2 Operating Mode Summer Automatic 1 Automatic 2 Fig 3 7 Switching the operating mode e g from Standby to Automatic 1 Place the ...

Page 14: ...ycles in the hot water time programme DHW Program 1 see section 3 4 5 All controllers integrated into the RoCon system via the CAN bus are also switched at a higher level to the operating mode Summer Operating mode Automatic 1 Timer programme Automatic heating and economy mode in accordance with the permanent timer programmes see section 3 4 7 HC Program 1 DHW Program 1 Operating mode Automatic 2 ...

Page 15: ...itch Change has been accepted Jump back to previous dis play More detailed explanations and possible setting values for this rotary switch setting can be seen in chapter 6 6 3 4 5 Temperature setting hot water generation The hot water set temperatures for hot water generation for each individual timer programme are determined in the rotary switch setting Place the rotary switch in the DHW Set Temp...

Page 16: ... in blocks of Monday to Friday Saturday to Sunday and Monday to Sunday Programme Time period switching cycle HC Program 1 Single day of the week Monday Tuesday 1st 2 3 06 00 22 00 Working week Monday to Friday 1st 2 3 06 00 22 00 Weekend Saturday to Sunday 1st 2 3 07 00 23 00 Entire week Monday to Sunday 1st 2 3 06 00 22 00 HC Program 2 See HC Program 1 1st 2 3 See HC Program 1 Tab 3 8 Menu struct...

Page 17: ...e one off extension of the room heating a If an automatic programme is activated the last applicable switching cycle is always extended In the time before switching cycle 1 the target room temperature set in the parameter T Room 1 Setpoint applies b In all other operating modes the target room temperature set in the parameter T Room 1 Setpoint applies The hot water generation is not affected The t...

Page 18: ...t has the necessary authority see also chapter 4 3 After activation of the Bus Scan a list of the equipment that was recognised is shown for selection in the display ex ternal equipment and local equipment After selection and confirming an external device the terminal function for this device is acti vated and the associated standard display for this device is shown in the display The operating co...

Page 19: ...ment To end terminal mode and restore operation of the assigned equipment to the control element at the level Remote Param the parameter No selection must be selected and acknowl edged After interim isolation from the power supply at the level Remote Param we always show the display as shown in fig 3 9 In order to be able to use the terminal function for con nected equipment a new Bus Scan must be...

Page 20: ...sually used by the heating expert The following special functions are possible Manual mode see section 3 5 1 Message display see section 7 Resetting to factory settings see section 3 6 12 More detailed explanations of these functions can be found in chapter 6 11 The call up of special functions does not depend on the setting on the rotary switch Depress the exit button for at least 5 secs Menu Spe...

Page 21: ...ings The Controller RoCon HP already has the basic configuration for the Daikin Altherma EHS X H However it needs to be adapted to the optionally connected accessories and the installation envi ronment during initial commissioning Adaption is carried out via the setting of parameters in the rotary switch setting Configuration Navigating with the rotary switch accesses either the next deeper level ...

Page 22: ...r controlled flow temperature regulation see section 3 6 4 Generally speaking the steepness of the heating characteristics describes the ratio of the flow tem perature change to the external temperature change The heating characteristic curve applies within the minimum and maximum temperature limits that have been set for the corre sponding heating circuit The room temperature measured in the livi...

Page 23: ...creed the structure of the floor and the underfloor heating system by con densation Before initial commissioning and activation of cooling operation set the maximum permissible system temperature in the minimum temper ature limit in the Controller RoCon HP parameter Min T Flow Cooling With the cooling characteristic curve the inflow target temper ature is adjusted to suit building conditions in ac...

Page 24: ...perature see tab 6 3 tab 6 16 parameter Room Influence Activation and deactivation of this function takes place via the parameter HC Function in the rotary switch position Configuration in level HC Configuration Parameter HC Function 0 Weather controlled flow tem perature regulation Parameter HC Function 1 Regulation according to fixed inflow target temperature In heating mode parameter T Flow Day...

Page 25: ... Open switching contacts only frost protection active b Operating modes Heating or Automatic 1 Automatic 2 active during switching cycles in day mode Closed switching contact heating IL1 The system operates according to the normal infeed tar get temperature according to the parameter settings in HC Configuration Heating Closed switching contact cooling IL2 The system operates according to the incr...

Page 26: ...t pump does not continue to operate alternative bivalence operation 8 When there is a hot water demand 9 When outside temperature parameter value Equilibrium Temp heat demand Room heating not for hot water demand Heat pump no longer operates in room heating mode below the value set in parameter Equilibrium Temp only in hot water mode Use An alternative bivalency operation room heating if the boile...

Page 27: ...e user or the heating technician is ignored when hot water is heated for disinfection purposes A connected circulation pump is automatically switched on during thermal disinfection Setting the parameters for legionella protection is carried out in the rotary switch setting Configuration in level DHW Configuration Using the factory settings the storage tank is heated at 03 30 hours if the target ho...

Page 28: ...Screed Program is a special function and is not interrupted by any other operating mode It can be activated only by the heating expert for the direct heating circuit and or the op tionally connected mixed heating circuits Each heating circuit must be separately activated Prior to start of the Screed Program the parameters Interlink fct and Room thermostat must have been deactivated In the event of...

Page 29: ...nge of the day at 00 00 On the day of activation we heat the remaining time at the programme of the first day Enter the expert code see section 3 6 1 The Setup level is displayed after entering Using the rotary push button select and check the param eters Interlink fct and Room thermostat whether they are deactivated see tab 6 1 Both parameters must be on Off before starting the screed function Pr...

Page 30: ... relays is displayed for allocation of relays see chapter 6 2 2 Select the relay to be tested with the rotary switch Confirm the changes with a brief push of the rotary switch The relay is activated Cancellation and jump back by briefly pressing the exit button or the rotary switch selecting a different menu using the rotary switch More detailed explanations and possible setting values for this fu...

Page 31: ... timer programme ON or from a separate timer programme OFF Circl Pump Interval Setting the interval control for an optional circulation pump Confirm the changes with a brief push of the rotary switch Setting parameters Confirm the changes with a brief push of the rotary switch The circulation pump is actuated in accordance with the settings made by the Controller RoCon HP Possible setting values f...

Page 32: ...Ds and authorisations in the RoCon system In the RoCon system the following functional IDs exist which are relevant for data exchange of the RoCon system components ID function System components Parameter Comments Heating circuit IDs Unique numbering of a heating circuit in the heating system in the RoCon system A maximum of 16 heating cir cuits can be controlled Daikin Altherma EHS X H RoCon BM1 ...

Page 33: ... heating circuit that is allocated to the room station by the heating circuit ID is still in the operating mode Summer The change in oper ating mode must therefore be undertaken at the room station On heating installations with heating circuit extensions we recommend not activating the Master RoCon function Setting Off and instead using the terminal function With all control units RoCon B1 B1 and ...

Page 34: ...ef push on the rotary switch see also section 4 2 The Basic Configuration of the RoCon device is loaded The message Starting Up is displayed The message Initialization is displayed The standard display for the current rotary switch setting is displayed At the RoCon device adjust the settings to suit the configu ration of the heating system see chapter 3 6 4 3 1 Allocating the terminal ID on the co...

Page 35: ...herma EHS X H d Remotely controlled unit for the entire RoCon system with terminal function activated The room station must be connected using a CAN bus line to a RoCon Controller installed in the Daikin Altherma EHS X H or to an EHS157068 mixer module No separate mains supply is nec essary for the room station Sequence for initial commissioning see also section 4 2 Set the rotary switch on the EH...

Page 36: ...57068 is deactivated 4 4 3 Allocating mixing module EHS157068 to a heat generator If just 1 heat generator is incorporated in the RoCon system adaption of the heat generator ID is not necessary see tab 4 1 If adaptions need to be made the value of the parameter Boiler Assignment see chapter 6 tab 6 15 must be set to the same value as the heat generator ID of the Daikin Altherma EHS X H that is int...

Page 37: ...ma EHS X H is commissioned for the first time or if it is fully reset During initial commissioning After resetting to factory settings Rotary switch setting Info Resetting to factory settings see chapter 3 6 12 Possibility 3 Rotary switch setting Info Turn power supply to Daikin Altherma EHS X H on Language Use Standard Config Yes No Basic Configuration Boiler Function Unmixed Circ Config BUS ID H...

Page 38: ...et Point Pressure HT NT Contact Max Pressuredrop Room thermostat Relay Test Interlink fct MF 1 Config Air Purge PWM Config Max Perform Pump Min Perform Pump HC Configuration HC Function Sensor Config Outside Config T Frost Protect Outside Temp Adap Storage Config Insulation Terminaladress Pressure Config Screed System Config Screed Program HC Assignment Heating T Outside lim day Cooling Start T Ou...

Page 39: ...itch setting Time Program 5 2 8 Rotary switch setting Remote Param Bus Scan No selection Contr BM1 BE1 X Mix Valve X Tab 5 9 Parameter in rotary switch setting Remote Param 5 2 9 Rotary switch setting Info Overview Mode Pump Ext EHS Water Pressure RT BPV T HS TV tDHW TVBH TA T HS Setpoint TR V T Outside TVBH2 Tliq2 TR2 tA2 T DHW Tdhw2 quiet T DHW Setpoint see also chapter 3 fig 3 5 T Return Flow R...

Page 40: ...iler Assignment HC Assignment Mixer Config HC Function Pump Mode T Outside lim day T Outside lim night Heat Slope Room Influence T Room Adj T Flow Day T Flow Night Max T Flow Min T Flow HC Adaption Slope Offset T Frost Protect Insulation Forced Performance Start T Out Cooling Max T Out Cooling T Flow Cooling start T Flow Cooling max Min T Flow Cooling T Flow Cooling Cooling Setpoint adj Relay Test...

Page 41: ... E Time Time in format hours minutes E E Keylock Function Release of the keylock function Off Button block cannot be activated On The button block can be activated using the rotary switch see chapter 3 3 E E Off On Off Access Rights Entering access code Setting character by character like a combination lock see chapter 3 6 1 E E 0 9 0000 1 RoCon U1 assign Display only on connected room station Fun...

Page 42: ... or run in high temperature mode N E 0 1 0 Mode SG Only if parameter SMART GRID 1 Used for a possible target temperature increase in the case of a SMART GRID start command 0 Comfort 5 K increase in target domestic hot water temperature 1 Standard 2 K increase in inflow target temperature and 5 K increase in target do mestic hot water temperature 2 Eco 5 K increase in inflow target temperature and ...

Page 43: ...e section 3 6 10 Off Deactivated On Start of Air Purge N E Off On Off PWM Config Max Perform Pump Upper limit for modulation of the pump output N E 20 100 100 1 Min Perform Pump Lower limit for modulation of the pump output N E 10 100 50 1 Sensor Config Outside Config Configuration of the optional external temperature sensor RoCon OT1 Off No sensor evaluation On Sensor evaluation activated This se...

Page 44: ...see chapter 4 1 This parameter determines which heating circuit is to be operated with it The direct heating circuit of the Daikin Altherma EHS X H is set as standard to heating circuit 0 see section 6 12 parameter Unmixed Circ Config N E Off 0 15 Off 1 Tab 6 1 Parameter in rotary switch setting Configuration level Setup Sub level Parameter Description Access Setting range Min Max Factory setting ...

Page 45: ...temperature Tdhw value of parameter T DHW 1 min 2 When there is a cooling or heating demand 3 When there is a hot water demand to the Backup Heater EKBUxx or the configured Backup Heater is required for heating support 4 When there is a malfunction 5 When sensor value TVBH 60 C 6 When the outdoor temperature parameter value Equilibrium Temp Heat pump continues to operate parallel bivalence operati...

Page 46: ...output J10 power supply A1P N E Tab 6 2 Parameter in rotary switch setting Configuration level System Depending on the version of the device software certain information parameters for the device not described in tab 6 2 can be displayed at this level For this see tab 6 12 Parameter Description Access Setting range Min Max Factory setting Increment BE HF Sub level Parameter Description Access Sett...

Page 47: ...ng the operating mode Automatic 1 or Automatic 2 Duration of the setback phase must be at least 6 hours Function At the start of the setback time the current room temperature is set as the target value for the following 4 hours The heating curve is determined by the Control ler from the inflow target temperatures that are necessary to maintain this room tem perature If the automatic adjustment of ...

Page 48: ... threshold hot water charging Setting of the temperature difference to which the temperature in the domestic hot water storage tank compared to the current target hot water temperature T DHW Setpoint can drop before the heat pump is switched on to provide hot water E E 2 20 K 7 K 1 K Timer BOH Delay time after which the reserve heating may support the heat pump in hot water charg ing see section 3...

Page 49: ... range Min Max Factory setting Increment BE HF T Reduced Target room temperature for the setback times for the permanent timer programmes Automatic 1 and Automatic 2 E E 5 40 C 15 C 0 5 C T Absence Target room temperature for the setback times for the temporary timer programmes Away and Vacation E E 5 40 C 15 C 0 5 C Tab 6 8 Parameter in rotary switch setting Set Temp Night 6 7 Rotary switch setti...

Page 50: ... 9 15 min DHW Program 1 In this menu we can parametrise the 1st timer programme for hot water generation 3 switch ing cycles with a resolution of 15 minutes can be set A separate entry for each weekday is possible Format On hh mm hh mm Off Also the cycles can be parametrised from Monday to Friday Saturday to Sunday and Mon day to Sunday E E see chapter 3 4 7 see tab 3 9 15 min DHW Program 2 In thi...

Page 51: ...ration is displayed in kWh S S kWh Qchhp The amount of heat in the additional heat generator for heating mode is displayed in kWh S S kWh Qsc The quantity of heat in the heat pump for cooling is displayed in kWh S S kWh Qch The quantity of heat in the heat pump for heating is displayed in kWh S S kWh QWP The total amount of heat in the heat pump is displayed in kWh S S kWh Qdhw The quantity of hea...

Page 52: ...uration and data bus con figuration can be deleted activated and deactivated with this parameter If you answer Yes to the enquiry about using the standard configuration when starting the unit for the first time the settings required for the basic equipment of the heat generator are activated automatical ly see section 6 2 1 tab 6 1 N E Inactive Active Delete Inactive Tab 6 14 Parameter in the leve...

Page 53: ...r limit for modulation of the pump output N E 0 100 50 1 Max Perform Pump Upper limit for modulation of the pump output N E 0 100 100 1 Sensor Config Outside Config Configuration of the outside temperature sensor Off Take over of outdoor temperature of heat generator to which the mixer module is allocated by the heat generator ID Parameter Boiler Assignment or no sensor eval uation On Sensor evalu...

Page 54: ...signed to the heating circuit Individual adaptation of the room temperature relevant for control Should a systematic deviation of the room temperature as measured by the EHS157034 from the actual temperature in the living area of this room be detected the measured value can be corrected by the set value E E 5 0 to 5 0 kW 0 0 K 1 K T Flow Day Only if parameter HC Function 1 Setting the inflow targe...

Page 55: ...unction 0 Setting the absolute lower limit of the cooling inflow target temperature The limitation is ef fective if a lower cooling inflow target temperature is determined based on other parameter settings N E 5 25 C 18 C 1 C T Flow Cooling Can be used only if the assigned heat generator has a cooling function Only if parameter HC Function 1 Setting the cooling inflow target temperature fixed valu...

Page 56: ... fault 7 1 2 Read Protocol The Protocol can be read in the Special Level see fig 7 3 The last received latest message is in the first position All other previous messages are then pushed backwards by one place when a new entry is made The 15th message will be deleted any time a new message is received E75 E75 E75 Special Level Manual Operation FA failure Protocol Special Level FA failure Protocol ...

Page 57: ...r mixing valve Info Overview Water Pressure T HS Sw Nr B1 U1 Sw Nr RTX RT Sw Nr Controller Info Sw Nr B1 U1 Sw Nr Controller Sw Nr RTX RT Info Sw Nr B1 U1 Sw Nr mixing valve Sw Nr mixing valve Fig 7 4 Software information of the controller components 7 x Errors malfunctions and messages Daikin RoCon HP Daikin Controller 008 1420844_13 02 2016 Operating instructions 57 7 2 Emergency operation In th...

Page 58: ... wall in the heat exchanger Heat pumping process In a closed coolant circuit the coolant absorbs heat from the surrounding air Compressing this coolant results in a higher temperature which can then be transferred to the heating unit thermodynamic circuit Heating characteristic curve Mathematical relationship between the external temperature and the target flow temperature synonym heating curve in...

Page 59: ...point ____ C Time period On Off On Off On Off HC Program 1 Monday Tuesday Wednesday Thursday Friday Saturday Sunday HC Program 2 Monday Tuesday Wednesday Thursday Friday Saturday Sunday Tab 9 1 Individual settings in the heating timer programmes Switching cycle 1 Switching cycle 2 Switching cycle 3 Temperature setting T DHW Setpoint 1 ____ C T DHW Setpoint 2 ____ C T DHW Setpoint 3 ____ C Time per...

Page 60: ...itching time programme Operating instructions 60 Daikin RoCon HP Daikin Controller 008 1420844_13 02 2016 9 x Notes 9 1 2 Parameter Enter your parameter changes in the table below Rotary switch setting Parameter levels Parameter Old value New value Date Comments Tab 9 4 Individual parameter modifications 9 1 3 IDs in the RoCon CAN bus system RoCon appliance ID Comments Tab 9 5 IDs in the RoCon CAN...

Page 61: ...9 x Notes Daikin RoCon HP Daikin Controller 008 1420844_13 02 2016 Operating instructions 61 9 2 Other items ...

Page 62: ...Operating instructions 62 Daikin RoCon HP Daikin Controller 008 1420844_13 02 2016 9 x Notes ...

Page 63: ...erature 14 In cooling mode 23 In heating mode 22 With weather dependent regulation 24 Information messages 51 56 L Language setting 18 Low tariff mains connection 58 M Malfunctions 56 Manual operation 20 Master RoCon function 33 36 41 Mixer module 24 34 36 N Normal operation 19 O Operating data overview 12 Operating elements 6 7 10 Exit button 10 Rotary push button 10 Rotary switch 9 Operating mod...

Page 64: ...008 1420844_13 02 2016 Copyright 2016 Daikin ...