Instruction
SiAU18-715
220
Operation Manual
Check
Before a long idle period
1. Operate the “FAN only” for several hours on a fine day to dry out the
inside.
• Press “MODE selector button” and select “FAN” operation.
• Press “ON/OFF button” and start operation.
2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
• When a multi outdoor unit is connected, make sure the heating operation is not used at the other room
before you use the fan operation.
NOTE
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
• If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the ser-
vice shop if this is the case.
• Operation with dirty filters :
(1) cannot deodorize the air.
(2) cannot clean the air.
(3) results in poor heating or cooling.
(4) may cause odour.
• The air purifying filter and Photocatalytic deodorizing filter cannot be reused, even if washed.
• In principle, there is no need to replace the photocatalytic deodorizing filter. Remove the dust peri-
odically with a vacuum cleaner. However, it is recommended to replace the filter in the following
cases.
(1) The paper material is torn or broken during cleaning.
(2) The filter has become extremely dirty after long use.
• To order air purifying filter or Photocatalytic deodorizing filter, contact to the service shop where you
bought the air conditioner.
• Dispose of old air filters as non-burnable waste and Photocatalytic deodorizing filters as
burnable waste.
Item
Part No.
Photocatalytic deodorizing filter (with frame)
KAZ917B41
Photocatalytic deodorizing filter (without frame)
KAZ917B42
Air purifying filter (with frame)
KAF925B41
Air purifying filter (without frame)
KAF925B42
Summary of Contents for E Series
Page 1: ...SiAU18 715 Applied Models Super Multi Plus Cooling Only Super Multi Plus Heat Pump E Series ...
Page 87: ...Refrigerant Flow for Each Operation Mode SiAU18 715 74 Refrigerant Circuit ...
Page 139: ...Indoor Unit SkyAir Models SiAU18 715 126 Function ...
Page 177: ...Test Operation and Field Setting for RA Indoor Unit SiAU18 715 164 Test Operation ...
Page 299: ...Instruction SiAU18 715 286 Operation Manual 2 6 Ceiling Suspended Type ...
Page 326: ...SiAU18 715 Service Check Function Troubleshooting 313 ...
Page 423: ...Method of Replacing The Inverter s Power Transistors Modules SiAU18 715 410 Troubleshooting ...
Page 443: ...Wiring Diagrams SiAU18 715 430 Appendix ...
Page 449: ...SiAU18 715 vi Index ...