Step 1. Select SETUP>Event>Alarm Link>Detector Abnormal Alarm. See Figure 4- 13.
Figure 4- 13
Step 2. Select failure event, and set parameter. See chart below Figure 4 -5.
Step 3. Click OK to save.
Note:
Refer to 2.3.4, if the zones Z1 and G interfaces directly connected in series with the line and
short-circuit alarm function is enabled, the device will issue a short circuit alarm signal.
If the zone is not connected detector circuit alarm enabled, the device will report the breaking
event, but does not affect use. If you want to eliminate the circuit, the zone can be isolated or two
2.2k resistor in series with the access zones.
Detector failure alarm is not controller by arm and disarm.
4.7 Video Alarm Config
Note:
Video alarm is not controlled by arm/disarm.
4.7.1 Motion Detection
Via system analysis of video image, when it detects mobile signal with preset sensitivity, it will
immediately enable video detection alarm. System supports three video detection types: motion
detection, video loss, tampering.
Step 1. Select SETUP>Event>Video Detect. See
Figure 4- 14
.