xStack® DGS-3120 Series Managed Switch Web UI Reference Guide
66
Parameter
Description
GVRP State
Click the radio buttons to enable or disable the GVRP State.
Join Time
Enter the Join Time value in milliseconds.
Leave Time
Enter the Leave Time value in milliseconds.
Leave All Time
Enter the Leave All Time value in milliseconds.
NNI BPDU Address
Used to determine the BPDU protocol address for GVRP in service provide site. It can
use 802.1d GVRP address, 802.1ad service provider GVRP address or a user defined
multicast address. The range of the user defined address is 0180C2000000 -
0180C2FFFFFF.
Click the
Apply
button to accept the changes made for each individual section.
NOTE:
The
Leave Time
value should be greater than twice the
Join Time
value. The
Leave All Time
value should be greater than the
Leave Time
value.
GVRP Port Settings
On this page the user can configure the GVRP port parameters.
To view the following window, click
L2 Features > VLAN > GVRP > GVRP Port Settings
, as show below:
Figure 4–12 GVRP Port Settings window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the unit you want to configure.
From Port / To Port
Select the starting and ending ports to use.
PVID
This field is used to manually assign a PVID to a VLAN. The Switch's default is to
assign all ports to the default VLAN with a VID of 1.The PVID is used by the port to
tag outgoing, untagged packets, and to make filtering decisions about incoming
Summary of Contents for xStack DGS-3120-24TC