TITLE
OPERATOR MANUAL
PAGE
PRINTERS
TELEIOS GRANDE H6
38
VERSION
2017JAN23/1
OUT OF
REVISED BY
MUNOZ, ANTONIO
64
FOR THE USER
d·gen International, Inc. - COMPANY PRIVATE (LEVEL 1)
NOT TO BE DISCLOSED TO UNAUTHORIZED PERSONS – PROHIBIDA SU DIVULGACIÓN A PERSONAS NO AUTORIZADAS
DO NOT REPRODUCE WITHOUT AUTHORIZATION – NO REPRODUCIR SIN AUTORIZACIÓN
3
The test print will look something like the image below. Using a loop or a microscope is possible to
check the middle line. If BDL and BDR are were not fired on the same spot means the bidirectional
compensation factor needs to be corrected.
4
In VALUES menu enter the BI-DIR COMPENSATION screen. Increase or decrease the BI-DIR
COMPENSATION value certain units. As a reference, if the carriage was moved to the highest point,
a value of 5 is introduced. If I raised the carriage to the highest point, I change only the “BI-DIR
COMPENSATION AT HIGH POSITION” parameter. If my carriage is in the middle position, I change
only the “BI-DIR COMPENSATION AT MEDIUM POSITION” parameter.