HEATER 1 SV.
This is the temperature set value. Press ENTER and modify this value using the arrow keys (Left/right to
change position and up/down to increase/decrease the value). Then press ENTER button again to
confirm. Press the right arrow key to turn the heater ON/OFF. X means OFF. O means ON.
HEATER 1 PV.
This is the present temperature value. This value is read by the thermocouple installed inside the
machine where the heating rods are located.
HEATER 1 OV.
Set temperature value’s over value in percentage. The thermostat allows the present temperature value
to fluctuate. The thermostat will switch off the heater if the PV exceeds the preset percentage of SV.
Example: SV=175°C / OV: 60%. The PV will vary from 175 to 175+105°C (60% of 175°C). The heater will
turn ON and OFF many times if the OV is very low. Increasing electric consumption.
HEATER 1 OFF.
Under AUTO conditions if the printer’s carriage goes back to the home position the fixation unit will
interpret that the printer is in standby. The heater will be turned off automatically after a certain period of
time (in seconds) from the moment the printer became idle.
HEATER 2.
The heater number two is basically a rubber heater located under the printing table for extra drying. The
power input to this rubber heater is shown in percentage. This printer does not include HEATER 2.
TORQUE.
Possible to regulate the torque value (in percentage) of the take-up unit located in the fixation unit. The
powder clutch equipped in the fixation unit is the device that regulates the torque.
TAKE-UP.
Possible to regulate the RPM (in percentage) of the take-up unit located in the fixation unit.
X means OFF. O means ON.
DIR.
Possible to change the direction of rotation of the take-up unit.
FORWARD: the lower rubber roller (traction) rotates counter-clockwise.
BACKWARD: the lower rubber roller (traction) rotates clockwise.
SUCTION.
Possible to switch ON/OFF the fume buster connected to the fixation unit.
X means OFF. O means ON.
SUCTION OFF.
Under AUTO conditions if the printer’s carriage goes back to the home position the fixation unit will
interpret that the printer is in standby. The fume buster will be turned off automatically after a certain
period of time (in seconds) from the moment the printer became idle.
ROLLER UP/DOWN.
Possible to higher/lower the up/down roller to make the media go through the heating rods for fixing.
X means DOWN. O means UP.
ROLLER DOWN.
Under AUTO conditions if the printer’s carriage goes back to the home position the fixation unit will
interpret that the printer is in standby. The up/down roller will be lowered automatically after a certain
period of time (in seconds) from the moment the printer became idle.