20
COMMAND
Description and Parameters
iremit ir N1 0 N2
Emit the specified IR command data from the specified IR output port.
N1
= 1~4
[IR output port]
N2
= {IR data}
[CYP format data]
irlearn 0
Initiate the unit’s IR capture function. The captured code will be
displayed in CYP format.
macro run N1
Run the specified macro immediately.
N1
= 1~32
[Macro number]
macro stop
Stop the execution of the current macro.
comconf N1 N2 N3 N4 N5
Set the serial port format, baud rate, data bits, parity and stop bits of
the serial port.
Available values for
N1
:
RS232
[RS-232 signal format]
RS422
[RS-422 signal format]
RS485
[RS-485 signal format]
Available values for
N2
:
4800
[4800
baud]
9600
[9600
baud]
19200 [19200
baud]
38400 [38400
baud]
57600 [57600
baud]
115200 [115200
baud]
250000
[250000
baud]
1000000
[1000000
baud]
N3
= 7~8
[Data Bits]
Available values for
N4
:
NONE [No
parity]