6.6.1 Macro Settings Tab
Click on the “Macro Settings” tab to execute or edit the settings for the
primary macro buttons. These macros can be executed by activating the 8
input triggers on the unit as well as via the WebGUI or Telnet.
1) Macros 1~8:
These align with Trigger Inputs 1~8. When a trigger is
activated the unit will execute the associated macro command.
By default, the unit comes with multiple macros pre-configured for testing
the unit’s functionality. These presets are:
Macro 1:
Sequentially close Relays 1 through 4 with a 100ms delay.
Macro 2:
Sequentially open Relays 1 through 4 with a 100ms delay.
Macro 3:
Sequentially toggle the state of Relays 1 through 4 with a
100ms delay.
Macro 4:
Sequentially send IR signals from emitters 1 through 4 with
a 100ms delay.
Macros 5~8:
Send a sample text string over the COM port with a
100ms delay afterwards.
Click on the macro buttons to demonstrate and test the various functions.
2) Macro Edit:
Clicking on the edit icon ( ) in any macro button will open
up the Macro Edit window. After all desired changes to the macro have
been made, click on the “Save Change” button to commit the changes to
memory.