4
6.2 Rear Panel
IR IN
TRIGGER IN
COMPORT
SERVICE
CONTROL
(POE)
POWER
DC 5V
1
5V
2 3 4
5
GND
6 7 8
5 4 3 2 1
RXD
RS232
RS422
RS485
TXD GND
RX+ RX-
TD-
TD+
GND
TD-
TD+
GND
2
1
3
4
5
6
1
DC 5V Port:
Plug the 5V DC power adapter into the unit and connect it
to an AC wall outlet for power. (Optional)
Note: Not required if the unit is being powered via PoE.
2
CONTROL (PoE) Port:
Connect directly, or through a network switch, to
your PC/laptop to control the unit via Telnet/WebGUI.
Note: If the unit is connected to a network switch that provides PoE then
no power adapter is required to power the unit.
3
SERVICE Port:
This slot is reserved for firmware update use only.
4
COMPORT Terminal Block:
Connect to the device you wish to control
via a 3(or 5)-pin adapter cable to send RS-232/422/485 commands from
the unit. Baud rates up to 115200 are supported. For pin connection
details please refer to the diagram above.
5
TRIGGER IN Terminal Block:
Connect to any device with trigger or
switch functionality such as window security alarms, motion detectors,
door switches, etc. Each of the 8 trigger inputs will activate the
associated macro when triggered. A minimum of 5V DC is required to
activate the trigger. For pin connection details please refer to the diagram
above.
6
IR IN Port:
Connect to the provided IR Extender to allow IR control of the
unit or for learning IR commands. Ensure that the remote being used is
within direct line-of-sight of the IR Extender.
Note: For additional IR learning details please refer to section 6.6.3.