Curtis PMC 1297 Manual
81
Preliminary on Verso page is set with right edge at 7 and 7/8,
and the top (as on the Recto page) at 1/4.
Program Menu Notes
1
Traction throttle types (see Throttle Wiring in Section 2)
Type 1:
5k
Ω
–0
Type 2:
single-ended 0–5V throttles and 3-wire pots
Type 3:
0–5k
Ω
Type 4:
wigwag 0–5V throttles and 3-wire pots
2
HPD types (see Section 3
A
, page 44)
Type 0:
No HPD.
Type 1:
HPD unless KSI and interlock inputs received before throttle request.
Type 2:
HPD unless KSI input is received before throttle request.
3
SRO types (see Section 3
A
, page 45)
Type 0:
No SRO.
Type 1:
SRO unless interlock input is received before a direction is selected.
Type 2:
SRO unless KSI + interlock inputs received before direction selected.
Type 3:
SRO unless KSI + int forward inputs received in that order.
4
Main contactor control types (see Section 3
C
, page 57)
On:
Interlock switch input required in addition to KSI to close contactor.
Off:
Contactor closes on KSI input alone.
5
Electromagnetic brake driver types (for detail on options, see Table 2, page 30)
Type 0:
no electromagnetic brake driver
Type 1:
Option 1
Type 2:
Option 2
Type 3:
Option 3
Type 4:
Option 4
6
Emergency reverse exit control type
(see Section 3
A
, page 42)
On:
To resume normal operation after emergency reversing has been
completed, the operator can either open both direction switches or
cycle the interlock switch.
Off:
To resume normal operation after emergency reversing has been
completed, the operator must cycle the interlock switch.
7
Hydraulic throttle types (see Hydraulic Throttle Wiring in Section 2)
Type 2:
single-ended 0–5V throttles and 3-wire pots
Type 4:
wigwag 0–5V throttles and 3-wire pots
6 — PROGRAMMER MENUS: Program Menu