B-
+
+
-
B-
+
SENSOR OUTPUT (0–5V)
J1
SENSOR
SENSOR GROUND
J1
SENSOR OUTPUT (0–5V)
SENSOR
Pot Low input (Pin 22)
Hyd. 0–5V input (Pin 21)
0–5V input (Pin 4)
Hyd. 0–5V input (Pin 21)
0–5V input (Pin 4)
Traction
Throttle
Hydraulic
Throttle
Traction
Throttle
Hydraulic
Throttle
Also, the controller recognizes the voltage between the wiper input and B- as the
applied throttle voltage and not the voltage from the voltage source relative to
the Pot Low input.
For either throttle input, if the 0–5V throttle input (Pin 4 or 21) exceeds
5.5V relative to B-, the controller will register a fault and shut down.
Fig. 6
Wiring for
0–5V throttles (“Type 2”).
(b) Ground-referenced
0–5V source
(a) Sensor-referenced
0–5V source
2 — INSTALLATION & WIRING: Throttles