INSTALLATION AND WIRING
MOUNTING THE CONTROLLER
The 1297 controller can be oriented in any position, and meets the IP53 ratings
for environmental protection against dust and water. However,
the location
should be carefully chosen to keep the controller clean and dry. If a clean,
dry mounting location cannot be found, a cover must be used to shield the
controller from water and contaminants.
When selecting the mounting position, be sure to also take into consid-
eration (1) that the built-in Status LED is visible only through the view port in
the label on top of the controller, and (2) that convenient access is needed at the
top of the controller to plug the programmer into its connector.
The outline and mounting hole dimensions for the 1297 controller are
shown in Figure 2. To ensure full rated power, the controller should be fastened
2
2 — INSTALLATION & WIRING: Controller
Fig. 2
Mounting dimensions, Curtis PMC 1297controller.
Dimensions in millimeters (and inches)
to a clean, flat metal surface with four 6 mm (1/4") diameter screws, using the
holes provided. Although not usually necessary, a thermal joint compound can
be used to improve heat conduction from the controller heatsink to the
mounting surface.
STATUS
INTEGRATED CONTROLLER
B-
TRACTION
PUMP
B+
Status LED
7.1 (0.28) dia.,
4 plcs
150 (5.9)
165 (6.5)
83 (3.27)
M8 thread, 4 plcs
M4 thread,
2 plcs
7.6
(0.3)
150
(5.9)
165
(6.5)
6.4
(0.25)
16
(0.63)
B-
J1
J2
J3
F2
F1