7 — DIAGNOSTICS & TROUBLESHOOTING
Table 5
TROUBLESHOOTING CHART
LED
PROGRAMMER
CODE
LCD DISPLAY
EXPLANATION
POSSIBLE CAUSE
1,1
DRIVE SENSOR
traction motor current sensor error
1. Incorrect traction motor wiring.
2. Controller defective.
1,2
HW FAILSAFE
self-test or watchdog fault
1. Controller defective.
1,3
DRIVE M-
external short of traction motor M-
1. Incorrect traction motor wiring.
to B-, or FET damage
2. Controller defective.
1,4
VALVE FAULT
Lowering valve fault
1. Lowering valve or connection open.
2,0
BDI LOW
battery needs to be recharged
1. Battery state-of-charge <20%.
2,1
THROTTLE WIPER HI
traction throttle wiper high
1. Throttle input wire shorted to B+.
2. Defective throttle pot.
3. Wrong throttle type selected.
THROTTLE WIPER LO
traction throttle wiper low
1. Throttle input wire open or shorted to B-.
2. Defective throttle pot.
3. Wrong throttle type selected.
2,2
PUMP SENSOR
pump motor current sensor error
1. Incorrect pump motor wiring.
2. Controller defective.
2,3
HPD
HPD sequencing error
1. Improper sequence of KSI, interlock,
and throttle inputs.
2. Wrong HPD type selected.
3. Misadjusted throttle pot.
4. Interlock switch open.
5. Sequencing delay too short.
6. Wrong throttle type selected.
SRO
SRO sequencing error
1. Improper sequence of KSI, interlock,
and direction inputs.
2. Wrong SRO type selected.
3. Misadjusted throttle pot.
4. Direction switch open.
5. Sequencing delay too short.
6. Wrong throttle type selected.
ANTI-TIEDOWN
mode switch activated at startup
1. Mode switch shorted to B+.
2. Mode switch “tied down” to select M2
permanently.
2,4
PUMP M-
external short of pump motor M-
1. Incorrect pump motor wiring.
to B-, or FET damage
2. Controller defective.
3,1
ANALOG MUX FAULT
tiller multiplexer error
1. MUX card not plugged in.
2. J2 not wired properly.
2. MUX card defective.
EMR REV WIRING
emergency reverse wiring fault
1. Emergency reverse wire or check wire
open.
3,2
MAIN CONT WELDED
main contactor welded
1. Main contactor stuck closed.
2. Main contactor driver shorted.
[chart continues on next page]