Curtis PMC 1297 Manual
A-18
APPENDIX A: GLOSSARY
APPENDIX D
PROGRAMMABLE PARAMETERS
The 1297’s programmable parameters are listed below in alphabetical order (by display name), along with the
default access levels, minimum and maximum allowable values, and default settings that are standard on
generic models. Cross references to the main entry in the manual are also provided.
Not included in this alphabetical listing are the hourmeter and battery discharge indicator (BDI)
parameters, which are listed separately.
Table D-1
PARAMETER RANGES AND DEFAULT SETTINGS
(for Generic 1297 Controllers with Rev. 01 Software)
1297
DEFAULT
MIN
MAX
DEFAULT
DESCRIPTION
PARAMETER
ACCESS
VALUE
VALUE
SETTING
UNITS
IN
MANUAL
ACCEL RATE,
M1-M2
OEM
0.1
3.0
0.5
seconds
page 24
ANTI-TIEDOWN
OEM
OFF
—
page 44
BOOST ENABLE
OEM
OFF
—
page 25
BRAKE C/L,
M1-M2
OEM
50
RATED CURRENT
*
1
RC*
1
amps
page 25
BRAKE RATE,
M1-M2
OEM
0.1
3.0
0.5
seconds
page 26
COAST DECEL
OEM
0.1
10.0
0.3
seconds
page 26
CREEP SPEED
OEM
0
25
0
percent
page 31
CURRENT RATIO
OEM
1
4
2
—
page 25
DECEL RATE,
M1-M2
OEM
0.1
10.0
3.0
seconds
page 26
DRIVE C/L,
M1-M2
OEM
50
RATED CURRENT
*
1
RC*
1
amps
page 24
E-M BRAKE DLY
OEM
0.0
30.0
3.0
seconds
page 29
E-M BRAKE TYPE
OEM
0
5
1
—
page 29
EMR ACCEL RATE
OEM
0.0
3.0
0.1
seconds
page 43
EMR DIR INT
OEM
ON
—
page 43
EMR REV C/L
OEM
50
RATED CURRENT
*
1
RC*
1
amps
page 43
EMR REV CHECK
OEM
OFF
—
page 43
EMR TIME LIMIT
OEM
OFF
—
page 43
FIELD CHECK
OEM
ON
—
page 42
FIELD MAP
OEM
0
100
50
percent
page 41
FIELD MAX
OEM
FIELD MIN
RATED CURRENT
*
2
RC*
2
amps
page 41
FIELD MIN
OEM
2.0
RESTRAINT
5.0
amps
page 41
FLD MAP START
OEM
25
RATED CURRENT
*
1
75
or
100
amps
page 41
H/S LATCH
OEM
OFF
—
page 31
HPD
OEM
0
2
1
—
page 44
HYD INHIBIT
OEM
OFF
—
page 48
HYD THRTL DB
OEM
0
40
10
percent
page 51
HYD THRTL MAP
OEM
20.0
80.0
50.0
percent
page 54
D-1
APPENDIX D: PROGRAMMABLE PARAMETERS
*
1
The
rated armature current for the traction motor
depends on the controller model:
1297-22XX (150 amps), 1297-23XX (250 amps), 1297-24XX (350 amps);
the default setting is the maximum value.
*
2
The
rated field current for the traction motor
depends on the controller model:
1297-22XX (25 amps), 1297-23XX (25 amps), 1297-24XX (35 amps);
the default setting is the maximum value.