A-19
APPENDIX A: GLOSSARY
HYD THRTL MAX
OEM
60
100
90
percent
page 53
HYD THRTL TYPE
OEM
(see sidebox
†
)
2
—
page 51
INT BRAKE C/L
OEM
50
RATED CURRENT
*
1
RC*
1
amps
page 27
INT BRAKE DLY
OEM
0.0
30.0
2.0
seconds
page 27
INT BRAKE RATE
OEM
0.0
3.0
0.1
seconds
page 27
INT OVERRIDE
OEM
OFF
—
page 31
LOAD COMP
OEM
0.0
25.0
0.0
percent
page 32
LOAD HOLD DLY
OEM
0.0
1.0
0.5
seconds
page 50
LV ACCEL
OEM
0.0
3.0
0.1
seconds
page 49
LV CHECK
OEM
ON
—
page 50
LV DECEL
OEM
0.0
3.0
0.1
seconds
page 50
LV DITHER
OEM
0
100
0
percent
page 49
LV MAX C/L
OEM
LV MIN C
/
L
3.0
1.0
amps
page 49
LV MIN C/L
OEM
0.0
LV MAX C
/
L
1.0
amps
page 49
MAIN CONT DIAG
OEM
ON
—
page 57
MAIN CONT INT
OEM
ON
—
page 57
MAIN OPEN DLY
OEM
0
40
0
seconds
page 57
MAX SPEED,
M1-M2
OEM
CREEP SPEED
100
100
percent
page 31
MUX ENABLE
OEM
OFF
—
page 58
NO LOAD C/L
OEM
0
PUMP C
/
L
0
amps
page 46
NO LOAD SPEED
OEM
0
100
100
percent
page 46
POT LOW CHECK
OEM
OFF
—
page 40
PUMP ACCEL
OEM
0.1
3.0
0.1
seconds
page 47
PUMP BDI L/O
OEM
OFF
—
page 48
PUMP BDI WARN
OEM
OFF
—
page 48
PUMP C/L
OEM
25
RATED CURRENT
*
3
RC*
3
amps
page 46
PUMP DECEL
OEM
0.1
3.0
0.1
seconds
page 47
PUMP LOCK C/L
OEM
25
RC
*
3
+50
RC*
3
amps
page 48
PUMP LOCK DLY
OEM
0.1
25.0
0.5
seconds
page 48
PUMP MAX SPEED
OEM
0
100
100
percent
page 46
RESTRAINT
OEM
FIELD MIN
RATED CURRENT
*
2
5.0
or
8.0
amps
page 27
SEQUENCING DLY
OEM
0.0
3.0
0.1
seconds
page 57
SRO
OEM
0
3
0
—
page 45
TAPER RATE
OEM
1
20
10
—
page 26
THROTTLE DB
OEM
0
40
10
percent
page 34
THROTTLE DECEL
OEM
0.1
1.0
0.3
seconds
page 26
THROTTLE MAP
OEM
20.0
80.0
50.0
percent
page 38
THROTTLE MAX
OEM
60
100
90
percent
page 36
THROTTLE TYPE
OEM
(see sidebox
††
)
2
—
page 33
VARIABLE BRAKE
OEM
ON
—
page 28
VARIABLE LIFT
OEM
OFF
—
page 56
VARIABLE LOWER
OEM
OFF
—
page 56
1297
DEFAULT
MIN
MAX
DEFAULT
DESCRIPTION
PARAMETER
ACCESS
VALUE
VALUE
SETTING
UNITS
IN
MANUAL
Table D-1
,
continued
D-2
APPENDIX D: PROGRAMMABLE PARAMETERS
††
Traction
throttle
types:
1=5k
Ω
–0
2=0–5V
3=0–5k
Ω
4=wigwag
†
Hydraulic
throttle
types:
2=0–5k
Ω
4=0-5V
*
3
The
rated armature current for the pump motor
depends on the controller model:
1297-22XX (200 amps), 1297-23XX (200 amps), 1297-24XX (300 amps);
the default setting is the maximum value.