Curtis PMC 1297 Manual
61
3
C
— PROGRAMMABLE SHARED PARAMETERS: Hourmeters
DIS TOTL HRS
The
total disable hours
parameter is used to set the total disable timer; it can
be adjusted between 0 and 250 hours, in 1 hour increments. If the total disable
timer expires, the traction fault speed and pump fault speed both go into effect.
DIS TRAC HRS
The
traction disable hours
parameter is used to set the traction disable timer;
it can be adjusted between 0 and 250 hours, in 1 hour increments. If the traction
disable timer expires, the traction fault speed goes into effect.
DIS PUMP HRS
The
pump disable hours
parameter is used to set the pump disable timer; it can
be adjusted between 0 and 250 hours, in 1 hour increments. If the pump disable
timer expires, the pump fault speed goes into effect.
TRAC FAULT SPD
The
traction fault speed
parameter sets the maximum drive speed in the event
the traction disable timer expires or the total disable timer expires; it can be
adjusted between 0–100% of Max Speed, and applies to both M1 Max Speed
and M2 Max Speed.
PUMP FAULT SPD
The
pump fault speed
parameter sets the maximum pump motor speed in the
event the pump disable timer expires or the total disable timer expires; it can be
adjusted between 0–100% of Pump Max Speed.
Hourmeter Disable Timer Setting