If the problem persists, contact AP/Cumberland or GSI Electronics
The EDGE Variable Output
does not vary correctly
Verify if the EDGE Variable Output configuration is set correctly on the control
unit
Verify if the Variable Output gives the nominal voltage of the voltage source with
a setpoint of 100%
If the problem persists, contact AP/Cumberland or GSI Electronics
Light Dimmer on EDGE 4IN-6R-2LD
Problem
Solution
The Light Dimmer AC Output is
always at 100%
Verify the wiring conforms to the wiring diagram.
Verify wires from the main voltage supply are connected to terminal
blocks J2 (LD1-L1 and LD1-L2\N) and J3 (LD2-L1 and LD2-L2\N).
Verify wires to the load are connected to terminal blocks J2 (LD1-L2\N
and LD1-OUT) and J3 (LD2-L2\N and LD2-OUT).
Verify the operation mode is set correctly.
If the problem persists, contact your dealer or GSI Electronics.
The Light Dimmer AC Output is
always “OFF”
Lights are not turning “ON”
Verify the AC wiring conforms to the wiring diagram.
Verify wires from the main voltage supply are connected to terminal
blocks J2 (LD1-L1 and LD1-L2\N) and J3 (LD2-L1 and LD2-L2\N).
Verify wires to the load are connected to terminal blocks J2 (LD1-L2\N
and LD1-OUT) and J3 (LD2-L2\N and LD2-OUT).
Verify the breakers are not open.
Verify the power wires are not cut.
Verify the power wires are correctly secured in the terminal blocks.
Verify the operation mode is set correctly.
The EDGE shows a Hardware trouble.
Verify there is not a short circuit at the Zone output.
If the problem persists, contact your dealer or GSI Electronics.
The Light Dimmer AC Output is not
working in manual mode
Verify that the selected mode is BYPASS mode.
If the problem persists, contact your dealer or GSI Electronics.
The Light Dimmer AC Output is not
working in automatic mode
Verify that the selected mode is Auto mode.
If the problem persists, contact your dealer or GSI Electronics.
The Light Dimmer AC Output does not
dim properly (LED, CFL, CCFL)
Verify the wiring conforms to the wiring diagram.
If the lights do not dim properly, try different waveform curves.
If the lights do not dim properly, reset the minimum and the maximum
light intensity.
Use skipped points to waive specific points on waveform curves.
Make sure you are using the same light model on the same zone.
110
890–00687
EDGE 2
Summary of Contents for 064-11343
Page 7: ...Chapter 1 Introduction Figure 1 2 Enclosure Identification 890 00687 EDGE 2 7...
Page 22: ...NOTES 22 890 00687 EDGE 2...
Page 30: ...Chapter 2 Pre Installation Planning 30 890 00687 EDGE 2...
Page 40: ...NOTES 40 890 00687 EDGE 2...
Page 58: ...NOTES 58 890 00687 EDGE 2...
Page 98: ...NOTES 98 890 00687 EDGE 2...
Page 112: ...NOTES 112 890 00687 EDGE 2...
Page 116: ...NOTES 116 890 00687 EDGE 2...
Page 120: ...NOTES 120 890 00687 EDGE 2...
Page 134: ...NOTES 134 890 00687 EDGE 2...
Page 135: ...F Extending a cable Best practice using a junction box 890 00687 EDGE 2 135...
Page 136: ...Appendix F Extending a cable Using of heat shrink tubing 136 890 00687 EDGE 2...