Verify if the power link is not cut: wire is cut
Verify if the power link length is below 1000 feet (300m) with the recommended
gage
If the problem persists, contact AP/Cumberland or GSI Electronics
Issues with inputs
sensors
Verify if the sensor wiring is conformed to the wiring diagrams
Verify if the sensor is connected at the right terminal
Verify if the sensor configuration is set correctly on the EDGE 2 Controller
If the problem persists, contact your AP/Cumberland or GSI Electronics
Issues with the 24V
outputs
Verify if the sensor wiring is conformed to the wiring diagrams
Verify if the sensor is connected at the right terminal
Ensure that the 24V output does not draw more than 50mA
If the problem persists, contact AP/Cumberland or GSI Electronics
Issues with 0-10Vdc
outputs
0-10Vdc output is not able to control the device. Ensure that the 0-10Vdc output
does not draw more than 100mA
Ensure that the 24V inputs are at least 18Vdc
Verify if the 0-10Vdc output is conformed to the wiring diagram
Ensure that the right output 0-10Vdc is used
Verify if the 0-10Vdc configuration is set correctly on the EDGE 2 Main Controller
The 0-10Vdc output follows the Variable Output. It is normal; each 0-10Vdc is in par-
allel with an 0-10Vdc Variable Output control output
If the problem persists, contact AP/Cumberland or GSI Electronics
The AC Switch (COMM-A
/ OUT-Ax, COMM-B
/OUT-Bx) does not acti-
vate the contactor coil or
the relay coil or the power
output is not activated
Verify if the led of AC switch is activated (OUT-Ax or OUT-Bx)
Verify if the AC switch wiring is conformed to the wiring diagram
Ensure that the right AC switch output is used
Verify if the AC switch configuration is set correctly on the EDGE 2 Main Controller
Verify if the load does not activate the protection. The current must be below
0.5Arms and higher than 0.1A
Verify if the load link is not cut
Verify if a voltage reaches the terminal COMM-A or COMM-B
If the problem persists, contact AP/Cumberland or GSI Electronics
The current sensor (CS_
Ax, CS_Bx) does read
Verify if the current sensors (CS_Ax, CS_Bx) wiring is conformed to the wiring
diagram
Verify if the current sensor configuration is set correctly on the EDGE 2 Controller
Verify if the load link is not cut
If the problem persists, contact AP/Cumberland or GSI Electronics
108
890–00687
EDGE 2
Summary of Contents for 064-11343
Page 7: ...Chapter 1 Introduction Figure 1 2 Enclosure Identification 890 00687 EDGE 2 7...
Page 22: ...NOTES 22 890 00687 EDGE 2...
Page 30: ...Chapter 2 Pre Installation Planning 30 890 00687 EDGE 2...
Page 40: ...NOTES 40 890 00687 EDGE 2...
Page 58: ...NOTES 58 890 00687 EDGE 2...
Page 98: ...NOTES 98 890 00687 EDGE 2...
Page 112: ...NOTES 112 890 00687 EDGE 2...
Page 116: ...NOTES 116 890 00687 EDGE 2...
Page 120: ...NOTES 120 890 00687 EDGE 2...
Page 134: ...NOTES 134 890 00687 EDGE 2...
Page 135: ...F Extending a cable Best practice using a junction box 890 00687 EDGE 2 135...
Page 136: ...Appendix F Extending a cable Using of heat shrink tubing 136 890 00687 EDGE 2...