GH DRIVER
9-
3
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
A1.30
Input filtering time
Calculation method: A1.30*0.5ms
0~30000
0.5ms
1
○
Synchronous/
Asynchronous
A1.31
Save
-
-
-
-
-
-
A1.32
A1.33
Automatic
correction
function of
midpoint of
analog quantity
0: do not start
1: start
0
,
1
-
0
○
Synchronous/
Asynchronous
A1.34
Time of section A of
curve S
set time of section A of curve S
0~2000
ms
10
○
Synchronous/
Asynchronous
A1.35
Time of section B of
curve S
set time of section B of curve S
0~2000
ms
10
○
Synchronous/
Asynchronous
A1.36
Time of section C of
curve S
set time of section C of curve S
0~2000
ms
10
○
Synchronous/
Asynchronous
A1.37
Time of section D of
curve S
set time of section D of curve S
0~2000
ms
10
○
Synchronous/
Asynchronous
A1.38
IO assign function
selection
Bit0: whether Q6 output as z?
0: z output
1: PLC control
Bit1: whether I5 as external IO interrupt?
0:don’t
1:do
Bit2: M0 exclusive brake function
0:start
1:PLC control
0~65535
-
0
△
Synchronous/
Asynchronous
A1.39
Port com1 function
selection
0: PLC communication
1: upper computer communication
0
,
1
-
0
×
Synchronous/
Asynchronous
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
A2.00
Control mode
selection
0: Terminal operation mode
1: Panel operation mode
2: MechatrolinkBus instruction control
3: Ethercat
4: M3
5: Canopen
6: Profibus
0~6
-
0
×
Synchronous/
Asynchronous
A2.01
Analog quantity
polarity selection
0: ±10V
1: 0-10V
0,1
-
1
×
Synchronous/
Asynchronous
User self-defined parameter A2