GH DRIVER
9-
4
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
A3.00
Modbus
Communication
status bit
0: Stop
1: Positive rotation
2: Neigative rotation
0~2
-
0
×
Synchronous/
Asynchronous
A3.01
Torque threshold
Setting the Threshold of Torque Output
0~65635
0.1NM
50
×
Synchronous/
Asynchronous
A3.02
Torque Control
Current
Upper Limit of
Potentiometer
Current upper limit of FV input 10V for
potentiometer torque control
0~65635
0.1A
10
×
Synchronous/
Asynchronous
A3.03
I5 low speed
control 10V
corresponding
maximum speed
When I5 is set as a low-speed function, the
maximum speed of the motor corresponding
to 10V analog voltage input
0~20000
rpm
500
×
Synchronous/
Asynchronous
A3.04
Save
-
-
-
-
-
-
~
A3.07
A3.08
Withdraw I0 port
0 speed spindle
locking time
Set Withdraw I0 port 0 speed spindle locking
time
0~20000
ms
100
×
Synchronous/
Asynchronous
A3.09
Withdraw I0 port
deceleration time
Set Withdraw I0 port deceleration time
0~20000
0.01s/
Krpm
80
×
Synchronous/
Asynchronous
A3.10
I5 emergency
stop decele ration
time
Deceleration time of motor when I5 is set as
input of external fault (emergency stop)
0~20000
0.01s/
Krpm
10
×
Synchronous/
Asynchronous
A3.11
Save
-
-
-
-
-
-
A3.12
Speed setting
during MODBUS
communication
control
Set speed setting during MODBUS
communication control
0~30000
rpm
0
×
Synchronous/
Asynchronous
A3.13
Speed Ring
Second Set
of Parameter
Effective Valve
The second set of PI parameters is the
effective speed threshold. The second set of
PI parameters is used when the speed is given
to be less than the maximum speed multiplied
by the percentage of the value.
0~
1000
-
0
×
Synchronous/
Asynchronous
A3.14
Second Kp of
Speed Ring
Setting the Second Speed Gain (Kp2)
0~
30000
-
140
×
Synchronous/
Asynchronous
A3.15
Second Ti of
Speed Ring
Setting the second velocity integral time
constant (Ti2)
0~
30000
-
15
×
Synchronous/
Asynchronous
A3.16
Save
-
-
-
-
-
-
~
A3.18
A3.19
Corresponding
speed when
analog voltage DA1
outputs 10V
Set corresponding speed when analog voltage
DA1 outputs 10V
0~
65635
rpm
6000
×
Synchronous/
Asynchronous
User self-defined parameter A3