GH DRIVER
9-
15
Protection parameter P1
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
P1.00
Save
-
-
-
-
-
-
P1.01
Bus voltage over
voltage alarm point
When bus voltage exceeds the value , alarm
over voltage OV1
0~10000
V
800
×
Synchronous
P1.02
Bus voltage under
voltage alarm point
When bus voltage is lower than the value , alarm
under voltage UV1
0~10000
V
300
×
Synchronous
P1.03
Encoder alarm
shielding
Encoder alarm shielding bit processing:
bit0: EL alarm shielding
bit1: EC alarm shielding
bit2: EP alarm shielding
Bit3: ES alarm shielding
0~65535
-
0
×
Synchronous
P1.04
PU alarm shielding
0: Start
1: Shielding PU
0
,
1
-
0
×
Synchronous/
Asynchronous
P1.05
Motor overheating
alarm
0: Normally closed
1: Normally open
2: Do not alarm OH3
0~2
-
1
×
Synchronous/
Asynchronous
P1.06
Motor speed alarm
point
Speed protect alarm upper limit
0~30000
rpm
8000
×
Synchronous/
Asynchronous
P1.07
Speed scope
decision
Used to decision speed reached, zero speed
0~3000.0
rpm
0
○
Synchronous/
Asynchronous
P1.08
Save
-
-
-
-
-
-
P1.09
Thermistor
measurement alarm
0: No start
Other: Representation temperature value, alarm
OH3 when measurement temperature
value pass the alarm value continue 1s
0~300
degree
0
○
Synchronous/
Asynchronous
P1.10
Position follow-
up error over proof
threshold
Position pulse counter over proof, representation
follow-up error reach 1.5 turn, endurance 50ms
alarm when setting 1.5000, the parameter set 0
shielding alarm
0~3.0000
Pulse
10000
×
Synchronous/
Asynchronous
P1.11
Alarm short circle
time
Let the bridge arm short circle when driver
alarm, and let the motor brake stop quickly
0~30000
ms
30
○
Synchronous/
Asynchronous
P1.12
Tamagawa
Encoder alarm
code
Read the alarm code from encoder, ALM byte
bit0: Over speed
bit2: Enumeration error
bit4: Encoder temperature over high
bit5: Many turn enumeration abnormal
bit6: Cell fault
0~65535
-
0
*
Synchronous/
Asynchronous
P1.13
Resolver fault
determining filtering
time
When resolver fault signal is kept over the time,
alarm EL
0~20000
ms
5
○
Synchronous/
Asynchronous
P1.14
OC4 alarm
shielding
1: Shielding
2: Start
0
,
1
-
0
×
Synchronous/
Asynchronous