Seres Reference Manual
56
When this command has been issued without the ‘,OTHER’ data field, the
baud rate of the current port will be changed accordingly. When the
‘,OTHER’ data field is specified (without the square brackets), a baud rate
change will occur for the other port.
The Seres will reply with the following response:
$>
5.3.8
$JCONN
This command is used to create a virtual circuit between the A and B port,
if needed. This allows you to through the Seres to the device on the
opposite port.
The virtual circuit command has the following form:
$JCONN,p<CR><LF>
Where the connection type, ‘p’, may be one of the following:
p
Description
AB
Specify ‘AB’ in order to connect the A port to the B port
X
Once a virtual circuit has been established, to remove the
virtual circuit, specify ‘X’ in this command to return the
current port to normal
5.3.9
$JDIFF
This command is used to change the differential mode of the Seres
receiver.
The structure of this command follows:
$JDIFF,diff<CR><LF>