Seres Reference Manual
104
•
Connect Pin-2-transmit (TX) of the serial port to the receive pin (RX) of the
separate GPS receiver or logging device.
•
Connect Pin-5-Common Ground of the seial port to the signal return or
common ground of the separate GPS receiver.
Figure B-2 illustrates the required interface between the Seres and device
that receives position information:
2 TX
RTCM
5 GND
GND
RX
SERES Port A / B
External Device
Figure B-2 RTCM Data Output Interface
Note - For successful communications, the baud rate of the Seres
port must be set to match that of the separate GPS receiver.
Additionally, you must interface the Seres to an RS-232C serial
port of the separate GPS receiver. Refer to Section 5.3.7 for
instructions related to setting the Seres baud rate.
External Correction Input
In this operating mode, an external correction device inputs RTCM
correction data through either Seres serial port. In order to accomplish
this, the Seres must be commanded to use external corrections using the
$JDIFF command.
To configure external correction input on Port B you must:
Summary of Contents for Seres
Page 1: ...Seres Reference Manual Part Number 875 0056 000 Date September 2002...
Page 6: ...Seres Reference Manual vi...
Page 14: ...Seres Reference Manual xiv...
Page 16: ...Seres Reference Manual xvi Table A 1 Specifications 100...
Page 34: ...Seres Reference Manual 14 Figure 1 1 WAAS Coverage...
Page 35: ...Seres Reference Manual 15 Figure 1 2 EGNOS Coverage...
Page 43: ...Seres Reference Manual 23...
Page 127: ...Seres Reference Manual 107...
Page 129: ...Seres Reference Manual 109...
Page 132: ...Seres Reference Manual 112...