Crystal Vision
Installation
Indigo 2 CoolFlow User Manual R1.3
8
20/06/2012
2.3 Connector pinout
Remote Control / GPI Connections
Each frame slot has six connections that are brought out to one or more of the four high
density D-Type connectors on the rear of the frame labelled Remote 1 to 4. These
connections are referred to as lines 'a' to 'f'. The functions assigned to them are dependent on
the module inserted in each slot, but a typical use is as a GPI line. Refer to the
documentation supplied with each Crystal Vision module to determine the actual functions
assigned.
Remote 1 and Remote 3 connections (26 way high density D-Type socket)
Pin number
Remote 1 - function
Remote 3 - function
1
+5.3V +/- 10% dc out
+5.3V +/- 10% dc out
2
Frame GND
Frame GND
3
Slot 9 GPI ‘a’
Slot 11 GPI ‘a’
4
Slot 6 GPI ‘a’
Slot 8 GPI ‘a’
5
Slot 5 GPI ‘a’
Slot 7 GPI ‘a’
6
Slot 5 GPI ‘b’
Slot 7 GPI ‘b’
7
Slot 2 GPI ‘a’
Slot 4 GPI ‘a’
8
Slot 1 GPI ‘a’
Slot 3 GPI ‘a’
9
Slot 1 GPI ‘b’
Slot 3 GPI ‘b’
10
Slot 10 GPI ‘a’
Slot 12 GPI ‘a’
11
Slot 10 GPI ‘b’
Slot 12 GPI ‘b’
12
Slot 9 GPI ‘b’
Slot 11 GPI ‘b’
13
Slot 6 GPI ‘c’
Slot 8 GPI ‘c’
14
Slot 6 GPI ‘b’
Slot 8 GPI ‘b’
15
Slot 5 GPI ‘c’
Slot 7 GPI ‘c’
16
Slot 2 GPI ‘b’
Slot 4 GPI ‘b’
17
Slot 2 GPI ‘c’
Slot 4 GPI ‘c’
18
Slot 1 GPI ‘c’
Slot 3 GPI ‘c’
19
Slot 10 GPI ‘c’
Slot 12 GPI ‘c’
20
Slot 10 GPI ‘d’
Slot 12 GPI ‘d’
21
Slot 9 GPI ‘d’
Slot 11 GPI ‘d’
22
Slot 9 GPI ‘c’
Slot 11 GPI ‘c’
23
Slot 6 GPI ‘d’
Slot 8 GPI ‘d’
24
Slot 5 GPI ‘d’
Slot 7 GPI ‘d’
25
Slot 2 GPI ‘d’
Slot 4 GPI ‘d’
26
Slot 1 GPI ‘d’
Slot 3 GPI ‘d’
Note:
The total current available from the 5.3V dc outputs is limited to approximately
1.5Amps.
To maintain EMC compliance only good quality screened cable assemblies should be
used.