Crystal Vision
Maintenance
Indigo 2 CoolFlow User Manual R1.3
33
20/06/2012
Front panel fan showing 3-pin connector and finger guard
Replacing the mains input fuses
The mains input fuses are fitted inside the IEC 320 connectors at the rear of the frame. A
spare fuse is also stored inside the connector. The fuse can only be accessed when the power
cord is disconnected.
The sequence is as follows: -
Disconnect ALL the power cords (one or two depending on configuration) from
the rear of the frame
Using a flat bladed screwdriver or similar tool gently lever out the fuse drawer
from the relevant IEC connector using the tab visible at the bottom of the
connector depression
Remove the defective fuse and replace with either the spare fuse or with a 5A,
250V time delay fuse
Replace the fuse drawer and reconnect the power cords
Rear connectors showing IEC mains inputs and fuse tray with main
and spare fuses