Crystal Vision
Installation
Indigo 2 CoolFlow User Manual R1.3
9
20/06/2012
Remote 2 and Remote 4 connections (26 way high density D-Type plug)
Pin number
Remote 2 - function
Remote 4 - function
1
Slot 5 GPI ‘e’
Slot 7 GPI ‘e’
2
Slot 5 GPI ‘f’
Slot 7 GPI ‘f’
3
Slot 6 GPI ‘a’
Slot 8 GPI ‘e’
4
Slot 6 GPI ‘f’
Slot 8 GPI ‘f’
5
Relay close on fault, upper
PSU
Relay close on fault, lower
PSU
6
Frame GND
Frame GND
7
RX+ bus RS422
N/C
8
TX- RS422 o/p Statesman
N/C
9
TX+ RS422 o/p Statesman
N/C
10
Slot 2 GPI ‘e’
Slot 4 GPI ‘e’
11
Slot 2 GPI ‘f’
Slot 4 GPI ‘f’
12
Slot 9 GPI ‘e’
Slot 11 GPI ‘e’
13
Slot 9 GPI ‘f’
Slot 11 GPI ‘f’
14
Relay common , upper PSU
Relay common , lower PSU
15
+5.3V +/- 10% dc out
N/C
16
RX- bus RS422
N/C
17
TX+ bus RS422
N/C
18
RX+ RS422 i/p Statesman
N/C
19
Slot 1 GPI ‘e’
Slot 3 GPI ‘e’
20
Slot 1 GPI ‘f’
Slot 3 GPI ‘f’
21
Slot 10 GPI ‘e’
Slot 12 GPI ‘e’
22
Slot 10 GPI ‘f’
Slot 12 GPI ‘f’
23
Relay open on fault, upper
PSU
Relay open on fault, lower
PSU
24
N/C N/C
25
TX- bus RS422
N/C
26
RX- RS422 i/p Statesman
N/C
Note:
The total current available from the 5.3V dc outputs is limited to approximately
1.5Amps.
To maintain EMC compliance only good quality screened cable assemblies should be
used.