Setting frame addresses
The frame address, which only relates to a non-passive panel, is normally set to zero.
However, unique frame addresses are required in Statesman systems where multiple frames
communicate with a single PC port. The address of a frame pair is set by its non-passive
panel.
Indigo active/remote/Statesman panel hardware settings – Frame address
Note:
Passive panels do not have a Frame Address switch.
Rotary Switch
Position
Description
Frame Address
Normally zero
This is usually the address of the frame from 0 to 15.
Note:
Set this switch to position 0, unless multiple frames communicate with a single PC port
in a Statesman system, or if multiple control panels connect to a single frame via one
multidrop cable.
Statesman will display the Hex switch settings 0 to E as frame addresses 1 to F; switch
setting F will be displayed as frame address 10.