Crystal Vision
Installation
Indigo 2 CoolFlow User Manual R1.3
15
20/06/2012
position for the other. For example it could be set to the Lower position for the Indigo 2SE
CoolFlow frame and Upper for an Indigo 2 CoolFlow or Indigo 1 CoolFlow frame.
The number of modules reported to the active display includes the PSUs and front
panel/frame as the Indigo front panel PIC and the two power supplies have an address and
are treated as modules. Refer to the address range table in Chapter 3 - 'Operating the active
panel' for more information.
The two frames should be connected so that control can pass from one frame to the other
using an RS422 serial link.
Note:
The switch will only have an effect the next time the front panel is powered up.
Establishing a serial link
This can be accomplished with a special cable linking the Remote 2 connectors or by using
a CAT-5 patch cable linking the '422 Bus Output' connectors.
Using a CAT-5 patch cable
A CAT-5 cable (TIA/EIA 568A CAT-5 PATCH) is plugged in the connectors labelled ‘422
Bus Output’ on each frame.
Using Remote 2 connectors
A special cable is connected between the 'Remote 2' D-Type connectors of the two frames.
The cable required uses two female 26 way high density D-Type sockets. These should be
connected with screened twisted pair cable containing two pairs. All the wiring is pin to pin.
Pins 16 and 7 should use one twisted pair, pins 17 and 25 the other. The screen should be
connected to pin 6 on both connectors.
Note:
The Comms LED will flash when communication has been established.
Signal
Female 26-way high density
D-Type plug pin No
Female 26-way high density
D-Type socket pin No
GND
6 / Shell
6/ Shell
PBRX +
17
17
PBRX -
25 25
PBTX +
7
7
PBTX -
16 16
Frame link cable connections
To ensure continued EMC compliance it is recommended to use high quality shielded twin
pair cable for RS422 cabling.