Software
Crestron
RoomView
identifier for each copy of a module. If any errors are generated at runtime, the
error message will give both the module name and the reference name, as
follows:
~TEMP1[7] <-- Array out of bounds in BRAND Z VCR
CONTROL.UF (Executive Planning Room)
~TEMP[16][17] <-- Array out of bounds in BRAND Z
VCR CONTROL.UF (Executive Planning Room)
~X$[10] <-- Array out of bounds in BRAND Z VCR
CONTROL.UF (Executive Planning Room)
The reference name makes it easier to track the instance of a module that is
causing the run-time error.
The
Handle
column is used internally by the control processor and can be
disregarded. The <none> task is a system internal task that is always present.
2-Series
Program Reset
Restarts the program stored in permanent memory, or flash PROM. If programs
exist both in internal and Compact Flash memory, the program in Compact
Flash will be loaded. Otherwise, the program in internal memory is loaded.
Use the console command "CFAUTORUN ON/OFF" to control the actions of
the control system when a Compact Flash card is inserted into a running system.
If CFAUTORUN is enabled, when a Compact Flash card is inserted or removed
the system automatically performs a program reset and the program in Compact
Flash will run. If CFAUTORUN is disabled, then a program reset must be
issued to switch programs.
If programs exist both in internal and Compact Flash memory, the program in
Compact Flash will be loaded. Otherwise, the program in internal memory is
loaded.
Control System Reboot
Restarts the control system and reloads the program that is currently stored in
memory. If programs exist both in internal and Compact Flash memory, the
program in Compact Flash will be loaded. Otherwise, the program in internal
memory is loaded.
Erase Program
Erases the current program.
If the Viewport detects a program in Compact Flash, then click
Yes
to erase the
program from Compact Flash, or
No
to erase the program from internal
memory. Click
Cancel
to cancel the operation.
Erase Web Pages
Deletes all Web pages from the internal Web server or Compact Flash.
If the Viewport detects Web pages in Compact Flash, then click
Yes
to erase the
Web pages from Compact Flash, or
No
to erase Web pages from internal
memory. Click
Cancel
to cancel the operation.
60
•
Crestron RoomView
Reference Guide - DOC. 6133