5. While powering up the QM-RMCRX, press and hold
ATL
and
K
on
the keyboard until the following text (or similar) appears in Viewport.
System Monitor [v1.001 (0001)]
12-19-01 16:25:23 32MB RAM, 4MB FLASH
CS>
NOTE:
After this, you can increase the baud rate to 115200 (for faster
communication) by pressing
F8
on the keyboard and then selecting 115200 from
the “Set Baud Rate” window.
6. At the Viewport prompt, type:
erase
and press
Enter
. The following
text appears in Viewport.
CS>erase
->25%->50%->75%->100%
Done
CS>
7. From Viewport, select
File Transfer | Update Control System
, or
press
Alt+U,
or from Viewport, select:
File Transfer | General file transfer | Xmodem 1K upload.
8. Find and select the QM-RMCRX CUZ file and click
Open
.
9.
Once “Completed Successfully” appears in Viewport, type
quit
at the
Viewport prompt and press
Enter
.
Battery Replacement
A Lithium battery is used to power the system clock within the QM-RMCRX.
Under normal conditions, it lasts for approximately 10 years. In the event that
the clock fails, only an authorized technician should replace it. Refer to the
following caution statement.
CAUTION:
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer's
instructions.
Passthrough Mode
Passthrough mode enables Viewport access to any serially controlled device that
is connected through a Crestron control processor, on the Cresnet network or the
Ethernet. That is, it allows direct communication between the PC and a network
device (effectively "passing through" the QM-RMCRX). While passthrough
mode is running, the program currently in memory is suspended and will not
execute. When passthrough mode is exited, the program resumes operation.
Entering passthrough mode for COM port B reinitializes it, which clears the data
for that port.
To establish communication, click
Functions | Enter Passthrough Mode
. Then
select the connection type that exists between the QM-RMCRX and the device.
The choices are Slot (for devices connected to the control system via one of the
card slots on the back panel), Cresnet, or Ethernet. If the connection is through a
34
•
QuickMedia™ Receiver/Processor: QM-RMCRX
Operations Guide - DOC. 6236A