Crestron
QM-RMCRX-BA
QuickMedia™ Receiver/Processor
Detail View of Video Output Control
Video Output Control Signals
SIGNAL TYPE AND NAME
DESCRIPTION
Digital output
<QM_Link>
Indicates that the QM connection with the QM transmitter is valid. The output
will remain high for as long as the QM connection is valid.
High/1 = QM connection valid
Low/0 = Connection broken at the QM input
Digital input
<SaveSkewPreset>
Saves the three R/G/B skew values, together with the peak and boost values,
into the preset number given by
<SkewPreset#>
or, when auto-compensation
is enabled, into the currently selected skew preset. The preset is saved when
the input is held high.
High/1 (level sensitive) = Save skew preset
Low/0 = No preset save
Digital input
<RecallSkewPreset>
This signal has NO effect if automatic video compensation is enabled.
Recalls the R/G/B skew values and peak/boost values stored in the preset
given by
<SkewPreset#>
when the input is held high.
High/1 (level sensitive) = Recall skew preset
Low/0 = No preset recall
Continued on the following page
Operations Guide – DOC. 6332
QuickMedia™ Receiver/Processor: QM-RMCRX-BA
•
47