ILT Shade Controller
Crestron
C2N-SSC-2
24
•
ILT Shade Controller: C2N-SSC-2
Operations & Installation Guide - DOC. 6318
C2N-SSC-2 Symbol Signal Descriptions (continued)
Signal Type & Name
Description
Digital output:
<
Sh1_Moving
>
Indicates that Shade 1 is moving. The output
remains high while the shade is moving.
This does not apply in limit-setting mode.
Note: Adjusting the upper or lower limit has no
effect on the state of the output.
High/1 = Shade 1 moving;
Low/0 = Shade 1 stopped
Digital output:
<
Sh1_LastDirOpen
>
Indicates that the current direction of movement
is toward the upper limit. If not currently moving,
indicates that the previous direction of
movement was toward the upper limit.
This does not apply in limit-setting mode.
Note: Adjusting the upper or lower limit has no
effect on the state of the output.
High/1 = Last direction open;
Low/0 = Last direction not open
Digital output:
<
Sh1_LastDirClose
>
Indicates that the current direction of movement
is toward the lower limit. If not currently moving,
indicates that the previous direction of
movement was toward the lower limit.
This does not apply in limit-setting mode.
Note: Adjusting the upper or lower limit has no
effect on the state of the output.
High/1 (rising edge) = Last direction close;
Low/0 = Last direction not close.
Digital input:
<
Sh1_SetPreset
>
Stores the current position of Shade 1 to the
preset number given by <
Sh1_Preset#
>, on the
rising edge of the input.
input has no effect if preset number is invalid.
High/1 (rising edge) = Save preset;
Low/0 = No effect
Digital input:
<
Sh1_RecallPreset
>
Moves Shade 1 to the preset position given by
<
Sh1_Preset#
>, on rising edge of the input.
The input has no effect if the preset number is
invalid, or if the preset has no position stored.
High/1 (rising edge) = Recall preset;
Low/0 = No effect
(continued on next page)