Page 22 of 62
“CABINET CONTROL” Error
CC POWER – Power ERROR.
C Test – Cup Board factory test not completed.
E Test – Environmental Board factory test not completed.
P Test – Port Board factory test not completed.
X Test – X Motor Board factory test not completed.
Y Test – Y Motor Board factory test not completed.
C Comms – Cup Board Communication issue.
E Comms – Environmental Board Communication issue.
P Comms – Port Board Communication issue.
X Comms – X Motor Board Communication issue.
Y Comms – Y Motor Board Communication issue.
C Reset – Cup Board reset unexpectedly.
E Reset – Environmental Board reset unexpectedly.
P Reset – Port Board reset unexpectedly.
X Reset – X Motor Board reset unexpectedly.
Y Reset – Y Motor Board reset unexpectedly.
“Tube Fill” - TUBE FILL ROUTINE
This function allows you to count the coins loaded in the top (separator) of the coin mech that will be routed to an
inventory tube. Note: If a coin mech is not installed, you will not be able to enter the program to display information.
Press key number 4 to enter mode and the total number of the coin type being loaded will be displayed and counted
in the vender controller as they are accepted. The controller will inhibit the acceptance of any coin which does not go
to a tube during this procedure. If a tube full status is detected, that coin type will be inhibited. When you finish
loading all coins press key number 1 to return to “Tube Fill”. Press key number 2 to scroll to the next routine.
“Test Modes” - TEST ROUTINE
This function allows you to diagnose different functions of the vender. Press key number 4 and the display will show
“Test vend”. For additional Dixie-Narco Factory Diagnostics refer to page 27. Press key number 2 or 3 to scroll
through the test routines available. Press key number 1 to return to “Test Modes”.
“Test Vend” - Vend Testing
This function allows you to test vend each column.
Press key number 4 and the display will show “Column A1”. Press key numbers 2 or 3 to scroll through the
columns available to run in motor test. Press and hold the Power Interrupt (PI) switch. Press key number 4 to
vend from the column displayed. Press key number 1 will return to “Test Vend”. Press key number 2 to scroll to
next test mode.
“Test Sel Switch” - Select Switch Test
This function allows you to test each selection.
Press key number 4 and the display will show “Selection 4”. Then press any key and the display will show the last
key number pressed.
Press and hold key number 1 for approximately 5 seconds will return to “Test Sel Switch”. Press key number 2
to scroll to the next test mode.
“Test Display” - Display Test
This function allows you to test all segments in the display. Press key number 4 and a lower case alphabet will
display, then turn off , then an upper case alphabet will display alternating until key number 1 has been pressed
to return to “Test Display”. Press key number 2 to scroll to next test mode.