ELECTRICAL POWER NEEDED
Refer to the Machine serial number plate to determine the correct voltage and frequency. In the US and Canada
this is 120Vac, 60Hz, 1P. In Europe, Australia, and other export countries, this is 220/230/240Vac, 50Hz, 1P
depending upon your country voltage. The serial plate also specifies the ampere rating of the Machine. This
Machine must be plugged into a properly rated receptacle with its own circuit protection (fuse or circuit breaker).
Equipment Nominal Power Requirements -
120V / 10.2 A = *1224W (1.224kw)
220V / 5.8 A = *1276W (1.276kw)
240V / 5.8 A = *1392W (1.392kw)
*Note: Watts = V x A
POWER SUPPLY CORD and GROUNDING REQUIREMENTS
In accordance with the National Electrical Code and Underwriters Laboratories Inc., domestic Vending Machines
are equipped with a three-wire power supply cord and Ground Fault Circuit Interrupter (GFCI). The GFCI device
is provided as part of the power supply cord and is either incorporated directly into the plug or mounted on the
cord adjacent to the plug.
WARNING
The GFCI protects against current leakage caused by ground faults. The GFCI
is not designed to protect against over current or short circuits.
DO NOT use the TEST and RESET buttons on the GFCI as an ON/OFF switch.
The Vending Machine supply cord MUST be plugged directly into a properly
grounded, 3 wire receptacle that is properly protected by a fuse or circuit
breaker. If the receptacle will not accept the power cord plug, it must be
replaced with a properly grounded, 3 wire receptacle in accordance with the
National Electrical Code and Local Codes and Ordinances. The work should be
done by a qualified electrician.
DO NOT USE A 3 WIRE TO 2 WIRE ADAPTOR.
DO NOT REMOVE THE GROUND PIN ON THE PLUG OR IN ANY WAY
BYPASS, MODIFY, DEFEAT, OR DESTROY THE GROUNDING SYSTEM OF THE
VENDING MACHINE.
DO NOT USE WITH AN EXTENSION CORD!
DO NOT REMOVE THE WARNING TAG ATTACHED TO THE POWER SUPPLY CORD.
The GFCI must be tested frequently and before each use in accordance with the instructions provided on the
GFCI device. IF THE GFCI DOES NOT PASS THE TEST, DO NOT USE THE MACHINE. Unplug the supply cord from
the receptacle and call the Crane Merchandising Systems Technical Support Group for assistance at 1-803-266-
5001.
It is recommended that the Machine be located so that the GFCI device will be accessible after the Machine is
installed. After installation, visually inspect the GFCI and power supply cord to be sure it is not crushed,
pinched, or stretched.