11.0 HELM CONTROLS INSTALLATION
11.0
HELM CONTROLS INSTALLATION
11.6.3e
Make sure that you connect the positive and negative connections to the house battery
through a 5 Amp circuit breaker.
11.6.3f
Make sure that you connect the fuel level connections to the fuel level sensor as follows:
�
Pin 4 – Analogue ground (black)
�
Pin 5 – Analogue input for fuel tank (Orange or white).
11.6.3g
Make sure that you connect the 7” screen (Refer to Figure 11.6.3g) with the harness
(033880). This harness (033880) has 2 connectors as follows:
�
1 harness connector with all the connections
�
1 harness connector with blanking plug.
11.6.3h
Make sure that you connect the blanking plug into port 1 (grey port on the 7” screen
(Figure 11.6.3g)).
11.6.3i
Make sure that you connect the harness connector with all the connections into port 2 (black
port on the 7” screen (Figure 11.6.3g)).
11.6.3j
Make sure that you connect the positive and negative connections to the house battery
through a 5 Amp circuit breaker.
11.6.3k
Make sure that you connect the fuel tank and level sensors to the 7” screen as follows:
�
Pin 2 – Fuel gauge input 3 (orange)
�
Pin 3 – Fuel gauge input 2 (orange)
�
Pin 4 – Fuel gauge input 1 (orange)
�
Pin 9 – Fuel gauge ground 3 (brown)
Figure 11.6.3g.
7” screen with
black and grey