The following factory values will be effective:
Settings
Factory settings
Operation
Comfort setting temperature
19°C
Boost duration
60 min.
Keypad lock
Disabled
User settings
Backlighting
L3
Eco mode temperature lowering level
-3,5°C
Frost protection temperature
7°C
Minimum set of Comfort setting
temperature
7°C
Maximum set of Comfort setting
temperature
30°C
Maximal Boost duration
60 min.
Maximum ambient temperature
for the automatic stop of the Boost
39°C
Installer settings
Automatic open window
detection
Enabled
PIN code protection
Disabled
PIN code
0000
To exit the user setting, press
twice.
14. Expert settings
14.1 Access
To access the expert settings in 5 steps. From Auto, Comfort, Eco or
Frost protection mode:
Information
displays
1
Information
displays
1
Press for 5
seconds
1
Press twice
2
Press simultaneously
for 10 seconds
4
Press for 10
seconds
3
Press briefly
5
Information
displays
= Expert settings
Setting sequence :
Ambient temperature sensor adjustement → Setting the power →
Restoring factory settings.
14.2 Ambient temperature sensor adjustement
• Overview
Important:
This operation is reserved for professional installers only; any
wrong changes would result in control anomalies.
In which case if the temperature measured(measured by reliable
thermometer) is different by at least 1°C or 2°C compared to the setting
temperature of the radiator. The calibration adjusts the temperature
measured by the ambient temperature sensor to compensate for a
deviation from + 5°C to -5°C by intervals of 0,1°C.
• Ambient temperature sensor adjustement
1- If the ambient temperature difference is negative, example:
Setting temperature (what you want) = 20°C.
Ambient temperature (what you read on a reliable thermometer) = 18°C.
Difference measured = -2°C.
Important:
Before carrying out the calibration it is recommended to
wait for 4h after the setting temperature modification to insure that the
ambient temperature is stabilized.
To correct, then proceed as follows:
Sensor temperature = 24°C
(The measured temperature may be different due to the location of the
thermostat in the room).