English
= Factory settings reset.
= Factory settings not reset
3- Press the key
for 5 seconds. The device returns to its initial
configuration and goes back automatically to Auto mode.
5 sec.
The following factory values will be effective:
Settings
Factory settings
Operation
Comfort setting temperature
19°C
Boost duration
60 min.
Keypad lock
Disabled
User settings
Backlighting
L3
Eco mode temperature lowering level
-3,5°C
Frost protection temperature
7°C
Minimum set of Comfort setting
temperature
7°C
Maximum set of Comfort setting
temperature
30°C
Maximal Boost duration
60 min.
Maximum ambient temperature
for the automatic stop of the Boost
39°C
Temperature unit
°C
Installer settings
Automatic open window
detection
Enabled
PIN code protection
Disabled
Value of the PIN code
0000
Expert settings
Power
500W
Indoor temperature monitoring
90°C
To exit the expert settings, press
3 times
.
15. Fitting and connections
15.1 Assembling of the controller on to the towel rails
Important:
Before carrying out any connection tasks, cut off the power
supply to the electronic regulator using the circuit breaker or the protection
fuse in the power supply circuit
Connection tasks must be carried out by a qualified professional installer.
• Assembling of the controller on to the towel rails
1- Fitting the joint to the cartridge heater (the cartridge)
Fit the joint (supplied) onto the cartridge heater to ensure that the latter
fits snugly into the electronic regulator:
Another o-ring, may
be present on the cartrid-
ge at this location, depen-
ding on the manufacturer.
It will in no way hinder
assembly of the product.
Leave it in place.
However, despite the
presence of o-ring you
still have to put o-rin-
g(supplied) in place.
Existing o-ring
Supplied o’ring
Bottom of the towel rails
2- Connecting the electronic regulator to the cartridge heater.
Bring the electronic regulator close to the cartridge heater, in order to connect
the two insulated female Faston lugs (the output contacts) to the two male lugs
on the cartridge. Press the lugs together firmly.
3- Fitting the electronic regulator to the cartridge heater
Fit the regulator to the base of the cartridge heater.
4- Fitting and tightening the electronic regulator onto the cartridge heater.
Keep the electronic regulator (B) pressed onto the base by exerting an
upwards force (and thus ensuring that joint is compressed (C) when you are
screwing in the cone-point set screw to the back of the product using an allen
key (A).
Tightening torque required: 0,5N.m.