English
Decrease the temperature measured by the ambient temperature sensor
by 2°C pressing
. In example, the measured temperature by the
sensor goes from 24°C to 22°C.
2- If the ambient temperature difference is positive, example:
Setting temperature (what you want) = 19°C.
Ambient temperature (what you read on a reliable thermometer) = 21°C.
Difference measured = +2°C.
To correct, then proceed as follows:
Sensor temperature = 21°C (The measured temperature may be different
due to the location of the thermostat in the room).
Increase the temperature measured by the ambient temperature sensor
by 2°C by pressing
. In example, the measured temperature by the
sensor goes from 21°C to 23°C.
To validate the new value press
. To exit the expert settings, press
3 times.
• The reset to zero of the sensor calibration
To put the value of the correction to "0", do the following :
1- When the temperature measured by the sensor appears, press
or
for at least 3 seconds.
3 sec.
2- To save and move to the next setting, press
. To exit the installer
settings, press
3 times
Important:
These changes should be performed by a qualified staff, it
should be performed in production or on site during the first installation.
14.3 Setting the power
To have a controller adapted to the towel rails and estimate the energy
consumed, it is essantial to set the power of the device.
1- Pre set value: 500W. Select a value between 500W and 1500W by
pressing
or
.
2- To save and move to the next setting, press
.
To exit the Expert settings, press
3 times.
14.4 Restoring factory settings
If the PIN code is disabled, the user and installer settings are reinitialized:
1- From the PIN code, press
.
appears briefly on the display.
2-
Appears . Press
or
to select
.
- 35 -