background image

INSTALL YOUR THERMOSTAT

Unlock and lift the thermostat cover.

Use the screws to secure the thermostat to the 

electrical box.

Replace the cover and lock.

Power up the thermostat.

After performing a test sequence, the thermostat should 

display the floor temperature. If not, refer to the trouble- 

shooting guide in this manual.

1

2

4

5

6

Warnings 

Before starting the installation of your new thermostat, please 

make sure that the breakers for your heating system are off at 

the main electrical panel!

The installation of this thermostat should be made by a 

certified electrician and must be installed in conformity 

with the national and local Electrical Codes.

Connect the heating floor by using the wire connectors 

load / line located on the back of the thermostat. Connect 

the ground wire to the screw in the electrical box intended 

for this purpose.

Connect the sensor.

(Only for control applications in F mode or with floor limit.)

3

Line 

Load

Floor heating

1

2

3

4

5

6

Make sure to firmly tighten the wire connectors for a secure 

connection. A loose connection can be a fire hazard.

TH1300ZB-C4

Installation Guide

Smart Floor Heating

Thermostat (3600 W)

zigbee 3.0

USER SETTINGS 

Get the setpoint to its minimum and hold the    

      button for 10 seconds to access the menu.

Press the       or       button to change 

the setting. 

Press the      and      buttons simultaneously to 

save and go to the next parameter. Continue 

to press until the end of the list to exit the 

menu.

Increasing or lowering the temperature 

To adjust the temperature, press       or      . The requested temperature 

will blink to confirm the new setpoint.

10 sec.

All the parameters of your thermostat can be programmed through the 

interface of your Control4 gateway.  

However, if your thermostat is not connected to you gateway and you wish to 

change the temperature format or the control cycle, you need to:

Settings which can be modified on the device directly:

Control 

Load

Display

Limit Floor Max

Aux

Sensor

Load power

0 watt to 3600 watt

Temperature format

°C or °F (default: °C)

Control mode

A (Air), F (Floor) (default: F)

Maximum floor temperature

(Only visible in A mode)

5 °C to 36 °C (default: OFF)

Floor sensor

10K or 12K (default: 10K)

Assignment of auxiliary output

OFF, EXP, 15 sec, 15 min (default: OFF)

The following table lists the settings that can be changed directly on 

the thermostat.

You can change other settings through your Control4 controller. *

5) Assigning the auxiliary output (A mode):  

The thermostat provides an auxiliary output that has three functions 

which are set from the user settings. 

15 sec function: 

Short cycle auxiliary output (15 seconds). Used for a 

heater controlled through an electronic relay (SSR). 

15 min function: 

Long cycle auxiliary output (15 minutes). 

Used for a 

heater controlled through an electromechanical relay or equipped with 

a fan. 

In the 15 sec and 15 min functions,

 

the thermostat controls the ambient 

temperature with the floor. Once the floor temperature has reached its 

limit, if the desired ambient temperature is not reached, the auxiliary 

output activates the heating device to reach the set temperature. (The 

auxiliary output acts as a second heating stage.)

EXP function: 

 Auxiliary output to connect several heating floors 

(TR1310 sold separately).

OFF function (default):

 Disables the auxiliary output.

3) The thermostat offers 2 temperature regulation modes:

F mode (default):

 Regulates the floor temperature by means of an 

external temperature sensor with the possibility to limit ambient 

temperature.

A mode: 

Regulates ambient temperature with the possibility to limit floor 

temperature by means of an external temperature sensor.  

4) Maximum floor temperature limit (A mode) 

The thermostat limits floor heating to the set temperature to ensure it 

does not exceed the selected limit. Ideal for protecting engineered 

wood floors.

Name

Parameters & settings

Display

When installing your floor heating system: add a second sensor in 

the floor whose tip can be stored in the thermostat housing. This 

additional sensor can be plugged in and used as a replacement 

without altering your floor heating system.

Sensor

Reviews: