Page 2: ...he manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or menta...

Page 3: ...unprofessional or improper way Observe the personnel qualifications Caution Keep a sufficient distance from heat sources Note To prevent damages to the device do not expose it to extreme temperatures extreme humidity or moisture Note Do not use abrasive cleaners or solvents to clean the device Information about the device Device description The device BP2F is a thermometer intended for temperature...

Page 4: ... 6 F 0 C to 200 C 32 F to 392 F 1 1 C 1 8 F Infrared sensor Measuring range 40 C to 280 C 40 F to 536 F Accuracy 40 C to 20 C 40 F to 68 F 3 C 5 4 F 20 C to 280 C 68 F to 536 F 1 1 C 1 8 F Operating conditions 0 C 32 F to 50 C 122 F with max 80 r F non condensing Storage conditions 20 C 4 F to 60 C 140 F with max 80 r F non condensing Functions hold function temperature indication C and F alarm fu...

Page 5: ...d This physical and unavoidable effect can falsify the measurement In this case the display shows either no measured values or they are incorrect Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement Temperature measurement with infrared sensor Info Vapours and smoke can influence the measurement Info Ensure that the surface to be measu...

Page 6: ... limit indication 16 flashes 2 Press the Scan 4 or LED 5 button to set the upper alarm limit 3 Press the SET button 6 again ð ON or OFF will flash in the measurement value indication 13 ð The indication for the upper alarm limit 16 flashes 4 Press the Scan 4 or LED 5 button to enable or disable the upper alarm limit ð ON indicates that the upper alarm threshold is enabled ð OFF indicates that the ...

Page 7: ...red values Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For fu...