background image

System 

Models

Standard Heating & Cooling Systems –

4 or 5 wires 

Standard Heat Only Systems 

Standard Central Air Conditioning 

Gas or Oil Heat 

All Models

Hydronic (Hot Water) Zone Heat – 2 wires

Electric Furnace 
Heat Pump (No Aux or Emergency Heat) 

 

Heat Pump (with Aux or Emergency Heat)

Baseboard Electric Heating or Line Voltage 

None

(120 or 240 Volt) 
Millivolt Heat Only Systems – 

Floor or Wall Furnaces 

All Models

Hydronic (Hot Water) Zone Heat – 3 wires

A.  Remove base from subbase:

 Loosen the screws on the base and remove.

B.  Mount switching subbase: 

Use the screws provided to mount the subbase or 

wallplate to wall (see Fig. 1).

C.  Attach wires to appropriate terminals:
 

•  For two wire systems (Heat Only or Cool Only).

 Replace subbase with wall-

plate. If you have a two-wire 

Heat Only

 system, attach one wire to 

and one to 

wire 

W. 

If you have a two-wire 

Cool Only 

system, attach one wire to 

and one to 

wire to 

Y. 

Tighten any unused terminals securely. (see Fig. 5 and 6).

 

•  If your system has more than two wires: 

Use the cross reference chart to 

determine correct wire connections. If you have a four-wire heat/cool system leave 
the factory installed jumper between 

RC

 and 

RH

 attached (see Fig 2.). If your sys-

tem has five wires remove the factory installed jumper between 

RC 

and 

RH 

(see 

Fig 3.).

 

•  Electric heat or single stage heat pump systems: 

These thermostats are 

configured from the factory to operate a heat/cool, fossil fuel (gas, oil, etc.) forced 
air system. This is correct for any system that DOES NOT require the thermostat 
to energize the fan on a call for heat. If your system is an electric heat or heat-
pump system that REQUIRES the thermostat to turn on the fan on a call for heat, 
remove the yellow factory-installed jumper wire from the 

terminal and connect  

it to the 

terminal. This will allow the thermostat to energize the fan immediately 

on a call for heat. If you are unsure if the heating system requires the thermostat 
to control the fan, contact a qualified heating and air conditioning service person. 
For single stage heat pump applications (no auxillary heat), install a short jumper 
wire (not included) across terminals 

and 

Y. 

If the system has a reversing valve 

connection energized in Cooling, attach it to 

O. 

If the system has a reversing valve 

connection energized in Heating, attach it to 

(see Fig. 4). This thermostat will not 

provide multi-stage heating or cooling.

D.  Mount Thermostat  Base: 

Gently  push  excess  wire  back  into  the  wall  opening 

and plug hole with a fire-resistant material, such as fiberglass insulation to prevent 
drafts from affecting thermostat operation. Mount the thermostat base to the sub-
base using the three captive screws on the thermostat base. (See Fig. 1) Tighten 
the screws securely. Proceed to Step #5.

Installation Instructions for:

Horizontal 

1F56N-444

Snap-Action
Vertical  

1E56N-444

Snap-Action

YOUR THERMOSTAT REPLACES

2

1

3

Assemble tools required: power drill, flat blade screwdriver, wire cutter/stripper, level.

Failure to follow and read all instructions carefully before installing or operat-
ing this control could cause personal injury and/or property damage.

THERMOSTAT FEATURES

PREPARATIONS

G

RC

Y

W

B

OFF

FAN

AUTO

ON

SYSTEM

COOL

HEAT

Mounting Screw

KEEP THIS AREA

CLEAR OF WIRES

Hole

in Wall

Mounting Screw

A

RH

O

6

Y

4

5

R

Mounting Hole

Mounting Hole

Figure 1. Thermostat subbase and wallplate

To prevent electrical shock and/or equipment damage, disconnect electrical pow-
er to the system at the main fuse or circuit breaker until installation is complete.

CAUTION

!

Before removing wires from old thermostat’s switching subbase, label each wire with 
the terminal designation it was removed from.

1.  Remove Old Thermostat: 

A standard heat/cool thermostat consists of three basic 

parts:

 

a.  The cover, which may be either a snap-on or hinge type.

 

b.  The base, which is removed by loosening all captive screws.

 

c.  The switching subbase, which is removed by unscrewing the mounting    

 

 

screws that hold it on the wall or adaptor plate.

Make a note here 

                      of the anticipator setting on the old thermostat for 

future reference and use in step 5.
The heat anticipator pointer, if adjustable, will be set at one of a series of numbers 
representing the current rating of the primary control in your furnace. The number will 
be one of the following: .2, .4, .8, etc. or 0.2, 0.4, 0.8, etc.

REMOVING OLD THERMOSTAT  

REMOVING OLD THERMOSTAT (cont’d)  

3

If no heat anticipator/indication is showing, do not be concerned; move on to the 
next step.

ATTENTION!

 This product does not contain mercury. However, this product may 

replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do  not  touch  any  spilled 
mercury. Wearing non-absorbent gloves, take up the spilled mercury and place into 
a container which can be sealed. If a cell becomes damaged, the unit should be 
discarded.
Mercury must not be discarded in household trash. When the unit this product is 
replacing is to be discarded, place in a suitable container. Refer to www.white-rodg-
ers.com for location to send product containing mercury.

4

MOUNTING AND WIRING

Do  not  use  on  circuits  exceeding  specified  voltage.  Higher  voltage  will 
damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or primary control to test. Short or 
incorrect wiring will damage thermostat and could cause personal injury 
and/or property damage.

Thermostat installation and all components of the system shall conform to 
Class II circuits per the NEC code.

WARNING

!

Take care when securing and routing wires so they do not short to adjacent 
terminals or rear of thermostat. Personal injury and/or property damage may 
occur.

CAUTION

!

TERMINAL CROSS REFERENCE CHART

 

New Thermostat 

Other Manufacturers’

 

Terminal Designation 

Terminal Designation

 

 

 

 

 

*

 

RH 

RH 

R5 

R

 

RC 

– 

 

G

 

W

 

Y6 

Y

*   These are four-wire, single-transformer systems. Factory installed jumper wire 
  between the RH and RC terminals must remain in place.

PART NO. 37-6881B

Replaces 37-6881A

0921

www.white-rodgers.com

Summary of Contents for 1E56N-444

Page 1: ...lat blade screwdriver wire cutter stripper level Failure to follow and read all instructions carefully before installing or operat ing this control could cause personal injury and or property damage THERMOSTAT FEATURES PREPARATIONS G RC Y W B OFF FAN AUTO ON SYSTEM COOL HEAT Mounting Screw KEEP THIS AREA CLEAR OF WIRES Hole in Wall Mounting Screw A RH O 6 Y 4 5 R Mounting Hole Mounting Hole Figure...

Page 2: ...even if the system switch is set to OFF the fan will run if the fan switch is in the ON position Thermostat on wallplate For heat only move the temperature lever to the highest temperature For cool only move the temperature lever to the lowest temperature SPECIFICATIONS ELECTRICAL DATA Switch Rating 24 VAC 30 VAC max Heating 0 15 to 1 2 Amps Cooling 0 to 1 5 Amps Anticipator Rating Heating Adjusta...

Page 3: ...3 System Switch not set to Cool Set System Switch to Cool and lower temp below room temp Heat Cool or Fan Runs 1 Possible short in wiring Check each wire connection to the thermostat to verify it is neatly looped under the terminals No extra Constantly 2 Possible short in thermostat wire should stick out from under the terminals 3 Possible short in heat cool fan system Furnace Cycles Too Fast See ...

Page 4: ...www white rodgers com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...

Page 5: ...ite rodgers com LÍNEA DE AYUDA PARA EL USUARIO 1 800 284 2925 White Rodgers es una división de Emerson Electric Co El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co ...

Page 6: ...dición de no enfriamiento cambie el termostato 3 El interruptor System no está ajustado en Cool Coloque el interruptor System en Cool y baje la temperatura de referencia por debajo de la temperatura ambiente El modo de calor frío o 1 Posible cortocircuito en los cables Revise la conexión de cada cable al termostato para asegurarse de que esté debidamente enroscada ventilador funciona 2 Posible cor...

Page 7: ...ición ON el ventilador funcionará de forma continua independiente mente de la posición del interruptor del sistema aunque el interruptor del sistema esté ajustado en OFF el ventilador funcionará si el interruptor del ventilador está en la posición ON Termostato montado en pared Para sólo calor mueva la palanca de temperatura a la tem peratura más alta Para sólo frío mueva la palanca de temperatura...

Page 8: ...ueridas taladro eléctrico destornillador de hoja plana tenazas desai slador nivel El no leer y seguir con cuidado todas las instrucciones antes de instalar o utilizar este control podría causar lesiones personales y o daños materiales DETALLES DEL TERMOSTATO PREPARACIÓN G RC Y W B OFF FAN AUTO ON SYSTEM COOL HEAT Tornillo de montaje MANTENGA ESTE LUGAR LIBRE DE CABLES Orificio en la pared Orificio...

Reviews: