background image

UV-C lamp(Applicable to the unit contains an UV-C lamp only)

This appliance contains an UV emitter. Do not stare at the light source.

 WARNING

This appliance contains a UV-C lamp. Read the maintenance instructions before opening the 

appliance.

1. Do not operate UV-C lamps outside of the appliance.

2. Appliances that are obviously damaged must not be operated.

3. Unintended use of the appliance or damage to the housing may result in the escape of dan-

    gerous UV-C radiation. 

    UV-C radiation may, even in small doses, cause harm to the eyes and skin. 

4. Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol 

    for the conducting USER 

    MAINTENANCE, it is recommended to disconnect the power. 

5. The UV-C lamp can not be cleaned, repaired and replaced.   

6. UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.

Safety 

Precautions

 Page 3

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

1.

   

Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific 

information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated 

greenhouse gas(on some models), please refer to the relevant label on the unit itself.

2.

 

Installation, service, maintenance and repair of this unit must be performed by a certified 

technician.

3.

 

Product uninstallation and recycling must be performed by a certified technician.

   

Sociable Remark

DISPOSAL: Do not dispose this product as unsorted municipal waste. 

Collection of such waste separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste.

For disposal, there are several possibilities:

When using this appliance in the European countries, the following information must be followed:

·   The municipality has established collection systems, where electronic waste can be disposed 

    of at least free of charge to the user.

·   When buying a new product, the retailer will take back the old product at least free of charge.

·   The manufacture will take back the old appliance for disposal at least free of charge to the user.

·   As old products contain valuable resources, they can be sold to scrap metal dealers. Wild 

    disposal of waste in forests and landscapes endangers your health when hazar do us 

    substances leak into the ground-water and find their way into the food chain. 

Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit 

in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol,etc.

Always transport your air conditioner in a vertical position and stand on a stable, level surface 

during use. 

Always contact a qualified person to carry out repairs. If the damaged power supply cord must 

be replaced with a new power supply cord obtained from the product manufacturer and not 

repaired. 

Hold the plug by the head of the power plug when taking it out.

Turn off the product when not in use.

Summary of Contents for CH-STLS-14AC

Page 1: ...stallation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference MOBILE AIR CONDITIONER Loca...

Page 2: ...ns Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Ambient Temperature Range For Unit Operating Troubleshooting Tips 01 10 10 10 Energy...

Page 3: ...grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit...

Page 4: ...should be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the...

Page 5: ...t be performed by a certi ed technician Sociable Remark DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is pr...

Page 6: ...he air conditioner to avoid any damage or hazard Flammable Refrigerant R32 is used within air conditioner When maintaining or disposing the air conditioner the refrigerant R32 or R290 shall be recover...

Page 7: ...tion should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be sto...

Page 8: ...herently resistant to being corroded or are suitably protected against being so corroded 9 Checks to electrical devices The area shall be checked with an appropriate refrigerant detector prior to and...

Page 9: ...on sharp edges or any other adverse environmental e ects The check shall also take into account the e ects of aging or continual vibration from sources such as compressors or fans 9 Cabling Under no c...

Page 10: ...instructions h Do not over ll 13 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of di erent refrigerants doe...

Page 11: ...the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Tran...

Page 12: ...for explanation purpose only Your machine may be slightly di erent The actual shape shall prevail The unit can be controlled by the unit control panel alone or with the remote controller This manual d...

Page 13: ...ts number means more cooling power for a larger room Be sure you are comparing only newer models to each other older models may appear to have a higher capacity but are actually the same Be sure to si...

Page 14: ...djustable window slider 1 Depending on the size of your window adjust the size of the window slider Use the combination of panels that best ts your window opening 2 If the length of the window require...

Page 15: ...ut side hole TYPE ONE Use the table below to determine what combinationof Window Sliders is correct for your window window slider window dimension mm window dimension inch a b 484 592 19 1 23 3 b c 59...

Page 16: ...rame see Fig 2 For some units attach the Window Kit Brace to the back of the hose panel to brace against the window so the window slider panels do not lean inward see Fig 3 3 Cut the non adhesive foam...

Page 17: ...hown see Fig 7 Foam seal B Adhesive type shorter Foam seal A Adhesive type Fig 7 2 Assembling the Sliding Window Adapter Only needed for Sliding Window applications Align both halves of the sliding wi...

Page 18: ...are installed in both sides of the window slider for improved rigidity 5 Cut the non adhesive foam seal C strip to match the window height Insert the foam seal between the glass and the window frame...

Page 19: ...lightly di erent than shown HEAT PUMP HOSE INSULATION FOAM only for heat pump mode NOTE When the unit is at heat mode the heat pump hose insulation foam must be xed in the hose of unit If you are expe...

Page 20: ...d angle Power Button Powers the unit on and o Operating Instructions Operating Instructions Control Panel Features NOTE The following control panels are for explanation purpose only The control panel...

Page 21: ...seconds again to stop the ION feature and the ION light turn dark the LED DISPLAY shows OF for 3 seconds for some units Sleep Button Used to initiate the SLEEP operation Pressing this button will inc...

Page 22: ...the desired time Press the TIMER button again within 5 seconds the Auto on start program is initiated And the TIMER ON indicator light illuminates Press the up or down button to select the desired Aut...

Page 23: ...t included can be attached to the adaptor if a longer hose length is required Place the end of the hose in the drain area you are using Water drainage During dehumidifying modes remove the upper drain...

Page 24: ...ill immediately stop However the fan motor will continue to operate this is normal Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Reinstall the b...

Page 25: ...nit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the applia...

Page 26: ...xhaust hose is not connected or is blocked There are heat sources inside the room Turn o the unit and clean the lter according to instructions Call a service technician to inspect the unit and top o r...

Page 27: ......

Page 28: ...Owner Name ____________________________________________________________________________________________ Address of Installation ________________________________________________________________________...

Page 29: ...urer for details THIS WARRANTY DOES NOT COVER Damages in shipping Damages caused by improper installation Damages as the result of not using product in accordance with provided instructions Damage fro...

Page 30: ...and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the servi...

Reviews: