background image

UV feature(on some models)

·  

Press SWING button and TIME button at the 

same time for 3 seconds to initiate UV-C lamp 

feature and the UV light illumiantes, the LED 

DISPLAY shows 'On' for 3 seconds for some 

units. The UV-C lamp feature will help to 

purify the air inside. Press it for 3 seconds 

again to stop the UV-C lamp feature and the 

UV light turn dark, the LED DISPLAY shows 

'OF' for 3 seconds for some units.

Up (    ) and Down (    ) Buttons

·  Used to increase/decrease temperature settings in 

1° increments in a range of 60°F/16°C to 86°F/30°C 

or the TIMER setting in a range of 0 ~ 24hrs.

·  To change between °F or °C, simultaneously press 

and hold the Up and Down buttons for 3 seconds.

Mode Button

·  Selects the desired operating mode. Each time you 

press the button, a mode is selected in a sequence 

that goes from AUTO, COOL, DRY, FAN and HEAT 

(Heat models only). The mode light illuminates and 

indicates the selected mode.

·  Controls the fan speed. Press to control the fan

speed in four steps - LOW, MID, HIGH and AUTO.

The selected fan speed light will illuminate.

NOTE: Applicable to models with the Constant 

Fan feature. In COOL or DRY mode, press the Fan 

button for 3 seconds to turn on or off the constant 

fan function.

When the function is turned on, the constant fan 

light will illuminate, indicating the fan will run 

constantly. When the function is turned off, the

constant fan light will go out, indicating that the 

fan will stop when the compressor stops.

Fan Button/Continuous fan(On some models) button

ION feature(on some models)

·  

Press SWING button and TIME button at 

the same time for 3 seconds to initiate ION 

feature and the ION light illumiantes, the LED 

DISPLAY shows 'On' for 3 seconds for some 

units. The ion generatoris energized and will 

help to purify the air inside. Press it for 3 

seconds again to stop the ION feature and 

the ION light turn dark, the LED DISPLAY 

shows 'OF' for 3 seconds for some units.

Sleep Button

·  

Used to initiate the SLEEP operation.

·  

Pressing this button will increase (during 

cooling operation) or decrease (during heating 

operation, applicable models) 2°F/1°C after 30 

minutes. The temperature will again increase 

(cooling) or decrease (heating) by another 

2°F/1°C after an additional 30 minutes. This 

new temperature will be maintained for 7 

hours before returning to the originally sele-

cted temperature. This ends the Sleep mode 

and the unit will continue to operate as orig-

inally programmed.

·  

Press SLEEP button for 

3 s

econds to initiate 

the filter feature.This feature is a reminder to 

clean the Air Filter for more efficient operation. 

The LED(the light above the button) will illumi-

nate after 250 hours of operation. 

LED Display

·  

Shows the set temperature in °F (Degrees 

Fahrenheit)

("°F" no display for some models) 

 

or °C (Degrees Celsius) and the Auto-timer 

settings. While on DRY and FAN modes, it 

shows the room temperature.

·  Shows Error codes and protection code:

The unit may stop operation or continue to 

run safely. If the error codes appear, wait for 

about 10 minutes. The problem may resolve 

itself. If not, disconnect the power, then 

connect it again. Turn the unit on. If the 

problem persists, disconnect the power and 

contact your nearest customer service center.  

Error code appears andbegins with the 

letters as the following in the window 

display of  indoor unit:EH(xx), EL(xx), EC(xx), 

PH(xx), PL(xx), PC(xx)

P1-Bottom tray is full--Connect the drain hose 

and drain the collected water away.If protection 

repeats,call for service.

Note: When one of the above malfunctions 

occurs, turn off the unit, and check for any 

obstructions. Restart the unit, if the malfunction 

is still present, turn off the unit and unplug the 

power cord. Contact the manufacturer or its 

service agents or a similar qualified person for 

service.

 Operating

Instructions

 Page 19 

Summary of Contents for CH-STLS-14AC

Page 1: ...stallation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference MOBILE AIR CONDITIONER Loca...

Page 2: ...ns Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Ambient Temperature Range For Unit Operating Troubleshooting Tips 01 10 10 10 Energy...

Page 3: ...grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit...

Page 4: ...should be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the...

Page 5: ...t be performed by a certi ed technician Sociable Remark DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is pr...

Page 6: ...he air conditioner to avoid any damage or hazard Flammable Refrigerant R32 is used within air conditioner When maintaining or disposing the air conditioner the refrigerant R32 or R290 shall be recover...

Page 7: ...tion should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be sto...

Page 8: ...herently resistant to being corroded or are suitably protected against being so corroded 9 Checks to electrical devices The area shall be checked with an appropriate refrigerant detector prior to and...

Page 9: ...on sharp edges or any other adverse environmental e ects The check shall also take into account the e ects of aging or continual vibration from sources such as compressors or fans 9 Cabling Under no c...

Page 10: ...instructions h Do not over ll 13 Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of di erent refrigerants doe...

Page 11: ...the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Tran...

Page 12: ...for explanation purpose only Your machine may be slightly di erent The actual shape shall prevail The unit can be controlled by the unit control panel alone or with the remote controller This manual d...

Page 13: ...ts number means more cooling power for a larger room Be sure you are comparing only newer models to each other older models may appear to have a higher capacity but are actually the same Be sure to si...

Page 14: ...djustable window slider 1 Depending on the size of your window adjust the size of the window slider Use the combination of panels that best ts your window opening 2 If the length of the window require...

Page 15: ...ut side hole TYPE ONE Use the table below to determine what combinationof Window Sliders is correct for your window window slider window dimension mm window dimension inch a b 484 592 19 1 23 3 b c 59...

Page 16: ...rame see Fig 2 For some units attach the Window Kit Brace to the back of the hose panel to brace against the window so the window slider panels do not lean inward see Fig 3 3 Cut the non adhesive foam...

Page 17: ...hown see Fig 7 Foam seal B Adhesive type shorter Foam seal A Adhesive type Fig 7 2 Assembling the Sliding Window Adapter Only needed for Sliding Window applications Align both halves of the sliding wi...

Page 18: ...are installed in both sides of the window slider for improved rigidity 5 Cut the non adhesive foam seal C strip to match the window height Insert the foam seal between the glass and the window frame...

Page 19: ...lightly di erent than shown HEAT PUMP HOSE INSULATION FOAM only for heat pump mode NOTE When the unit is at heat mode the heat pump hose insulation foam must be xed in the hose of unit If you are expe...

Page 20: ...d angle Power Button Powers the unit on and o Operating Instructions Operating Instructions Control Panel Features NOTE The following control panels are for explanation purpose only The control panel...

Page 21: ...seconds again to stop the ION feature and the ION light turn dark the LED DISPLAY shows OF for 3 seconds for some units Sleep Button Used to initiate the SLEEP operation Pressing this button will inc...

Page 22: ...the desired time Press the TIMER button again within 5 seconds the Auto on start program is initiated And the TIMER ON indicator light illuminates Press the up or down button to select the desired Aut...

Page 23: ...t included can be attached to the adaptor if a longer hose length is required Place the end of the hose in the drain area you are using Water drainage During dehumidifying modes remove the upper drain...

Page 24: ...ill immediately stop However the fan motor will continue to operate this is normal Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Reinstall the b...

Page 25: ...nit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the applia...

Page 26: ...xhaust hose is not connected or is blocked There are heat sources inside the room Turn o the unit and clean the lter according to instructions Call a service technician to inspect the unit and top o r...

Page 27: ......

Page 28: ...Owner Name ____________________________________________________________________________________________ Address of Installation ________________________________________________________________________...

Page 29: ...urer for details THIS WARRANTY DOES NOT COVER Damages in shipping Damages caused by improper installation Damages as the result of not using product in accordance with provided instructions Damage fro...

Page 30: ...and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the servi...

Reviews: