Water drainage(For Heating Mode)
Note: Make sure the drain hose is lower than the
bottom tray drain outlet.
that there are no kinks that will stop the warter flowing.
Place the end of the hose into the drain and make sure
the end of the hose is down to let the water flow
smoothly.(See Figs with . Do never let it up.(See Figs
with ). When the continuous drain hose is not used,
ensure that the corresponding drain plug and knob
are installed firmly to prevent leakage.
NOTE: Make sure the hose is secure so there are no
leaks. Direct the hose toward the drain, making sure
√
X
drain hose
adaptor
√
delivery lift <1.8m
X
drain hose
adaptor
Continuous
drain hose
Remove the
lower drain plug
√
· While operating in heat pump mode, the unit will
produce condensate that must be drained. You must
install the drain hose when operating in heat mode. To
install the drain hose, remove the plug from the drain
port and attach the included hose. The universal drain
adaptor can be attached to the end of the included
hose. A 3/4” hose (not included) can be attached to
the adaptor if a longer hose length is required. Place
the end of the hose in the drain area you are using.
Water drainage
· During dehumidifying modes, remove the upper drain plug from
the back of the unit, install the drain hose. For the models without
drain connector, just attach the drain hose to the hole. Place the
open end of the hose directly over the drain area in your basement
floor.
Remove the
upper drain plug
√
Continuous
drain hose
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect the
unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the
air flow direction automatically:
· When the Power is ON, the louver opens fully.
· Press the SWING button on the panel or remote
controller to initiate the Auto swing feature. The
louver willl swing up and down automatically.
· Please do not adjust the louver manually.
AUTO-RESTART
If the unit breaks off unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.