UD70
Issue code: 70nu2
Parameters
10-1
10
Parameters
10.1 UD70
set-up
parameters
The set-up parameters take effect only after the
UD70
has been reset. This
occurs when any of the following actions is performed:
AC
supply is applied to the Drive
A
REINIT
instruction in a
DPL
program is executed
When Reset Target
Reset Target is selected in the Run
Run menu in the DPL Toolkit
The value 1070 is written to parameter #88.01
The following table lists all the
UD70
set-up parameters.
Function
Parameter
Min Value Max Value
Default
Large Option Module
code
#17.01
N/A
N/A
1 = UD70
Software version of the
Large Option Module
operating system
#17.02
N/A
N/A
N/A
DPL line number where
trip occured
#17.03
Debugging mode only
Available resources (%)
#17.04
0
100
N/A
#17.04 gives an indication of the level of processor resource available by indicating
the percentage of a 128ms period over which the
BACKGROUND
task will operate.
ANSI Serial address
#17.05
11
99
11
This parameter defines the addresses for
serial
communications. Range: 11 to 99.
RS485 Mode
#17.06
1
12
1
This parameter sets the mode for
serial
communications. (See below).
RS485 baud rate
(Mode 1, 5, 6 and 7)
#17.07
300
38400
4800
This parameter sets the baud rate: 24 represents 2400... 192 represents 19200, etc.
Maximum is 38400 which is set by a code of 38.
RS485 parameter pointer 1
#17.08
01.00
19.50
0.00
Defines the source parameter for data to be transmitted to a remote Drive when
used in mode 2 and mode 4 communications, and the destination parameter for data
received when using mode 3.
RS485 parameter pointer 2
#17.09
01.00
19.50
0.00
Defines the destination parameter for data received from the remote Drive when
using mode 4 serial communications.