Diagnostics
ERROR:
Expression too complex — break into parts
ERROR:
Invalid Drive type
ERROR:
Label duplicated
A label of the same name has been given more than once. Check other
Tasks for duplication.
ERROR:
Label is in another task
The
GOTO
instruction is in a different Task to where the label is defined.
The label needs to be in the same Task as the
GOTO
instruction.
ERROR:
Label not found
A label has not been defined. Define a label.
ERROR:
Operators only allowed on integer arguments
ERROR:
Maximum bit-field size is 32
The Bit-field invert Operator has been used and the specified bit-field is
greater than 32. Re-specify the size of the bit-field.
ERROR:
Syntax error
ERROR:
Variable has not been initialized
Before a variable can be used as an argument, it must be given a starting
value. This is typically performed in the
INITIAL
task. Remember that
variable names are case sensitive.
ERROR:
Variable is not an array
Warning messages
WARNING:
Title will be truncated to 64 characters
WARNING:
Version will be truncated to 8 characters
WARNING:
Possible loss of accuracy in assignment
This warning indicates that a floating-point number has been assigned to an
integer parameter. For example:
#1.14 = 3.142
As #1.14 can be set only with integer variables #1.14 now = 3.0